Export limit exceeded: 21624 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (21624 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-4239 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4240 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4241 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4242 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4243 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4244 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4245 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4246 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4497 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4247 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4252 1 Tenda 2 I22, I22 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4248 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4249 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4250 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4251 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4113 1 Tenda 2 Tx9 Pro, Tx9 Pro Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2022-30339 1 Intel 1 Integrated Sensor Solution 2025-01-27 6 Medium
Out-of-bounds read in firmware for the Intel(R) Integrated Sensor Solution before versions 5.4.2.4579v3, 5.4.1.4479 and 5.0.0.4143 may allow a privileged user to potentially enable denial of service via local access.
CVE-2022-30531 2 Intel, Microsoft 2 Iris Xe Max Dedicated Graphics, Windows 2025-01-27 4.4 Medium
Out-of-bounds read in the Intel(R) Iris(R) Xe MAX drivers for Windows before version 100.0.5.1474 may allow a privileged user to potentially enable information disclosure via local access.
CVE-2022-34346 1 Intel 1 Media Software Development Kit 2025-01-27 4.8 Medium
Out-of-bounds read in the Intel(R) Media SDK software before version 22.2.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-30259 1 Eprosima 1 Fast Dds 2025-01-27 8.2 High
FastDDS is a C++ implementation of the DDS (Data Distribution Service) standard of the OMG (Object Management Group). Prior to versions 2.14.1, 2.13.5, 2.10.4, and 2.6.8, when a publisher serves malformed `RTPS` packet, heap buffer overflow occurs on the subscriber. This can remotely crash any Fast-DDS process, potentially leading to a DOS attack. Versions 2.14.1, 2.13.5, 2.10.4, and 2.6.8 contain a patch for the issue.