Export limit exceeded: 22776 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (22776 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-3128 | 1 Mitsubishielectric | 1 Smartrtu | 2026-04-15 | 9.8 Critical |
| A remote unauthenticated attacker who has bypassed authentication could execute arbitrary OS commands to disclose, tamper with, destroy or delete information in Mitsubishi Electric smartRTU, or cause a denial-of service condition on the product. | ||||
| CVE-2025-25050 | 2026-04-15 | 8.8 High | ||
| An out-of-bounds write vulnerability exists in the cv_upgrade_sensor_firmware functionality of Dell ControlVault3 prior to 5.15.10.14 and Dell ControlVault 3 Plus prior to 6.2.26.36. A specially crafted ControlVault API call can lead to an out-of-bounds write. An attacker can issue an API call to trigger this vulnerability. | ||||
| CVE-2018-25154 | 1 Gnu | 1 Barcode | 2026-04-15 | 9.8 Critical |
| GNU Barcode 0.99 contains a buffer overflow vulnerability in its code 93 encoding process that allows attackers to trigger memory corruption. Attackers can exploit boundary errors during input file processing to potentially execute arbitrary code on the affected system. | ||||
| CVE-2025-37129 | 2 Arubanetworks, Hp | 2 Edgeconnect Enterprise, Arubaos | 2026-04-15 | 6.7 Medium |
| A vulnerable feature in the command line interface of EdgeConnect SD-WAN could allow an authenticated attacker to exploit built-in script execution capabilities. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system if the feature is enabled without proper security measures. | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2009-20011 | 1 Contentkeeper Technologies | 1 Contentkeeper | 2026-04-15 | N/A |
| ContentKeeper Web Appliance (now maintained by Impero Software) versions prior to 125.10 are vulnerable to remote command execution due to insecure handling of file uploads via the mimencode CGI utility. The vulnerability allows unauthenticated attackers to upload and execute arbitrary scripts as the Apache user. Additionally, the exploit can optionally escalate privileges by abusing insecure PATH usage in the benetool binary, resulting in root-level access if successful. | ||||
| CVE-2025-9976 | 1 Dassault | 1 Station Launcher App | 2026-04-15 | 9 Critical |
| An OS Command Injection vulnerability affecting Station Launcher App in 3DEXPERIENCE platform from Release 3DEXPERIENCE R2022x through Release 3DEXPERIENCE R2025x could allow an attacker to execute arbitrary code on the user's machine. | ||||
| CVE-2025-41663 | 2026-04-15 | 9.8 Critical | ||
| For u-link Management API an unauthenticated remote attacker in a man-in-the-middle position can inject arbitrary commands in responses returned by WWH servers, which are then executed with elevated privileges. To get into such a position, clients would need to use insecure proxy configurations. | ||||
| CVE-2025-36529 | 2026-04-15 | 7.2 High | ||
| An OS command injection issue exists in multiple versions of TB-eye network recorders and AHD recorders. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who is logging in to the device. | ||||
| CVE-2025-5743 | 2026-04-15 | 5.5 Medium | ||
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-8696 | 1 Isc | 1 Stork | 2026-04-15 | 7.5 High |
| If an unauthenticated user sends a large amount of data to the Stork UI, it may cause memory and disk use problems for the system running the Stork server. This issue affects Stork versions 1.0.0 through 2.3.0. | ||||
| CVE-2025-22367 | 2026-04-15 | N/A | ||
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. | ||||
| CVE-2025-8697 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-15388 | 1 Qno Technology | 1 Vpn Firewall | 2026-04-15 | 8.8 High |
| VPN Firewall developed by QNO Technology has an OS Command Injection vulnerability, allowing authenticated remote attackers to inject arbitrary OS commands and execute them on the server. | ||||
| CVE-2025-55118 | 1 Bmc | 1 Control-m/agent | 2026-04-15 | 8.9 High |
| Memory corruptions can be remotely triggered in the Control-M/Agent when SSL/TLS communication is configured. The issue occurs in the following cases: * Control-M/Agent 9.0.20: SSL/TLS configuration is set to the non-default setting "use_openssl=n"; * Control-M/Agent 9.0.21 and 9.0.22: Agent router configuration uses the non-default settings "JAVA_AR=N" and "use_openssl=n" | ||||
| CVE-2025-1883 | 2026-04-15 | 7.8 High | ||
| Out-Of-Bounds Write vulnerability exists in the OBJ file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted OBJÂ file. | ||||
| CVE-2013-10049 | 2026-04-15 | N/A | ||
| An OS command injection vulnerability exists in multiple Raidsonic NAS devices—specifically tested on IB-NAS5220 and IB-NAS4220—via the unauthenticated timeHandler.cgi endpoint exposed through the web interface. The CGI script fails to properly sanitize user-supplied input in the timeZone parameter of a POST request, allowing remote attackers to inject arbitrary shell commands. | ||||
| CVE-2025-27079 | 2026-04-15 | 6 Medium | ||
| A vulnerability in the file creation process on the command line interface of AOS-8 Instant and AOS-10 AP could allow an authenticated remote attacker to perform remote code execution (RCE). Successful exploitation could allow an attacker to execute arbitrary operating system commands on the underlying operating system leading to potential system compromise. | ||||
| CVE-2025-10622 | 1 Redhat | 4 Satellite, Satellite Capsule, Satellite Maintenance and 1 more | 2026-04-15 | 8 High |
| A flaw was found in Red Hat Satellite (Foreman component). This vulnerability allows an authenticated user with edit_settings permissions to achieve arbitrary command execution on the underlying operating system via insufficient server-side validation of command whitelisting. | ||||