Export limit exceeded: 363150 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 12010 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (12010 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-24511 | 2 Intel, Linux | 3 Ethernet I350 Series, I350, Linux Kernel | 2026-04-15 | 3.3 Low |
| Improper initialization in the Linux kernel-mode driver for some Intel(R) I350 Series Ethernet before version 5.19.2 may allow an authenticated user to potentially enable Information disclosure via data exposure. | ||||
| CVE-2025-10910 | 2026-04-15 | N/A | ||
| A flaw in the binding process of Govee’s cloud platform and devices allows a remote attacker to bind an existing, online Govee device to the attacker’s account, resulting in full control of the device and removal of the device from its legitimate owner’s account. The server‑side API allows device association using a set of identifiers: "device", "sku", "type", and a client‑computed "value", that are not cryptographically bound to a secret originating from the device itself. The vulnerability has been verified for the Govee H6056 - lamp device in firmware version 1.08.13, but may affect also other Govee cloud‑connected devices. The vendor is investigating other potentially affected models. The vendor has deployed server-side security enhancements and automatic firmware updates for model H6056. Most of H6056 devices have been successfully patched through automatic updates. Remaining H6056 users with upgradeable hardware versions must manually update firmware through the Govee Home app while keeping their device WiFi-connected. Users should open the Govee Home app, tap their H6056 device card to enter the device details page, tap the settings icon in the upper right corner, navigate to Device Information section (Firmware Version), and tap the Update button to install the security patch immediately. Govee H6056 devices with hardware versions 1.00.10 or 1.00.11 cannot receive firmware update due to hardware limitations. | ||||
| CVE-2025-22853 | 1 Intel | 1 Tdx Module Software | 2026-04-15 | 2.3 Low |
| Improper synchronization in the firmware for some Intel(R) TDX may allow a privileged user to potentially enable escalation of privilege via local access. | ||||
| CVE-2025-14303 | 1 Msi | 2 Intel 600, Intel 700 | 2026-04-15 | 6.8 Medium |
| Certain motherboard models developed by MSI has a Protection Mechanism Failure vulnerability. Because IOMMU was not properly enabled, unauthenticated physical attackers can use a DMA-capable PCIe device to read and write arbitrary physical memory before the OS kernel and its security features are loaded. | ||||
| CVE-2025-3114 | 2026-04-15 | N/A | ||
| Code Execution via Malicious Files: Attackers can create specially crafted files with embedded code that may execute without adequate security validation, potentially leading to system compromise. Sandbox Bypass Vulnerability: A flaw in the TERR security mechanism allows attackers to bypass sandbox restrictions, enabling the execution of untrusted code without appropriate controls. | ||||
| CVE-2024-5995 | 1 Scshr | 1 Hr Portal | 2026-04-15 | 8.8 High |
| The notification emails sent by Soar Cloud HR Portal contain a link with a embedded session. The expiration of the session is not properly configured, remaining valid for more than 7 days and can be reused. | ||||
| CVE-2025-24302 | 1 Intel | 1 Tinycbor | 2026-04-15 | 6.7 Medium |
| Uncontrolled recursion for some TinyCBOR libraries maintained by Intel(R) before version 0.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2025-6438 | 2026-04-15 | N/A | ||
| A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access when the server is accessed via the network using an application account. | ||||
| CVE-2025-53969 | 1 Cognex | 2 In-sight Camera Firmware, In-sight Explorer | 2026-04-15 | 8.8 High |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose a service implementing a proprietary protocol on TCP port 1069 to allow the client-side software, such as the In-Sight Explorer tool, to perform management operations such as changing network settings or modifying users' access to the device. | ||||
| CVE-2024-34328 | 1 Sielox | 1 Anyware | 2026-04-15 | 6.3 Medium |
| An open redirect in Sielox AnyWare v2.1.2 allows attackers to execute a man-in-the-middle attack via a crafted URL. | ||||
| CVE-2024-10220 | 1 Kubernetes | 1 Kubelet | 2026-04-15 | 8.1 High |
| The Kubernetes kubelet component allows arbitrary command execution via specially crafted gitRepo volumes.This issue affects kubelet: through 1.28.11, from 1.29.0 through 1.29.6, from 1.30.0 through 1.30.2. | ||||
| CVE-2025-30075 | 2 Microsoft, Mindmanager | 2 Windows, Mindmanager | 2026-04-15 | 2.2 Low |
| In Alludo MindManager before 25.0.208 on Windows, attackers could potentially execute code as other local users on the same machine if they could write DLL files to directories within victims' DLL search paths. | ||||
| CVE-2025-47241 | 2026-04-15 | 4 Medium | ||
| In browser-use (aka Browser Use) before 0.1.45, URL parsing of allowed_domains is mishandled because userinfo can be placed in the authority component. | ||||
| CVE-2025-10229 | 2026-04-15 | 4.3 Medium | ||
| A vulnerability has been found in Freshwork up to 1.2.3. This impacts an unknown function of the file /api/v2/logout. Such manipulation of the argument post_logout_redirect_uri leads to open redirect. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.2.3 will fix this issue. You should upgrade the affected component. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-56948 | 2026-04-15 | 6.5 Medium | ||
| An issue in KuGou Technology CO. LTD KuGou Music iOS v20.0.0 allows attackers to access sensitive user information via supplying a crafted link. | ||||
| CVE-2024-9044 | 2026-04-15 | N/A | ||
| A XML External Entity (XXE) vulnerability has been identified in Easy Tax Client Software 2023 1.2 and earlier across multiple platforms, including Windows, Linux, and macOS. | ||||
| CVE-2025-64484 | 1 Oauth2 Proxy Project | 1 Oauth2 Proxy | 2026-04-15 | 8.5 High |
| OAuth2-Proxy is an open-source tool that can act as either a standalone reverse proxy or a middleware component integrated into existing reverse proxy or load balancer setups. In versions prior to 7.13.0, all deployments of OAuth2 Proxy in front of applications that normalize underscores to dashes in HTTP headers (e.g., WSGI-based frameworks such as Django, Flask, FastAPI, and PHP applications). Authenticated users can inject underscore variants of X-Forwarded-* headers that bypass the proxy’s filtering logic, potentially escalating privileges in the upstream app. OAuth2 Proxy authentication/authorization itself is not compromised. The problem has been patched with v7.13.0. By default all specified headers will now be normalized, meaning that both capitalization and the use of underscores (_) versus dashes (-) will be ignored when matching headers to be stripped. For example, both `X-Forwarded-For` and `X_Forwarded-for` will now be treated as equivalent and stripped away. For those who have a rational that requires keeping a similar looking header and not stripping it, the maintainers introduced a new configuration field for Headers managed through the AlphaConfig called `InsecureSkipHeaderNormalization`. As a workaround, ensure filtering and processing logic in upstream services don't treat underscores and hyphens in Headers the same way. | ||||
| CVE-2025-2365 | 1 Crmeb | 1 Crmeb Java | 2026-04-15 | 6.3 Medium |
| A vulnerability, which was classified as problematic, has been found in crmeb_java up to 1.3.4. Affected by this issue is the function webHook of the file WeChatMessageController.java. The manipulation leads to xml external entity reference. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2019-25282 | 2026-04-15 | 9.8 Critical | ||
| V-SOL GPON/EPON OLT Platform v2.03 contains an open redirect vulnerability in the script that allows attackers to manipulate the 'parent' GET parameter. Attackers can craft malicious links that redirect logged-in users to arbitrary websites by exploiting improper input validation in the redirect mechanism. | ||||
| CVE-2025-4677 | 1 Abb | 2 Webpro Snmp Card Powervalue, Webpro Snmp Card Powervalue Ul | 2026-04-15 | 6.5 Medium |
| Insufficient Session Expiration vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. | ||||