Export limit exceeded: 11756 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (11756 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-20397 | 2026-04-15 | 5.2 Medium | ||
| A vulnerability in the bootloader of Cisco NX-OS Software could allow an unauthenticated attacker with physical access to an affected device, or an authenticated, local attacker with administrative credentials, to bypass NX-OS image signature verification. This vulnerability is due to insecure bootloader settings. An attacker could exploit this vulnerability by executing a series of bootloader commands. A successful exploit could allow the attacker to bypass NX-OS image signature verification and load unverified software. | ||||
| CVE-2025-41459 | 2026-04-15 | 7.8 High | ||
| Insufficient protection against brute-force and runtime manipulation in the local authentication component in Two App Studio Journey 5.5.6 on iOS allows local attackers to bypass biometric and PIN-based access control via repeated PIN attempts or dynamic code injection. | ||||
| CVE-2025-21618 | 2026-04-15 | 7.5 High | ||
| NiceGUI is an easy-to-use, Python-based UI framework. Prior to 2.9.1, authenticating with NiceGUI logged in the user for all browsers, including browsers in incognito mode. This vulnerability is fixed in 2.9.1. | ||||
| CVE-2025-28231 | 2026-04-15 | 9.1 Critical | ||
| Incorrect access control in Itel Electronics IP Stream v1.7.0.6 allows unauthorized attackers to execute arbitrary commands with Administrator privileges. | ||||
| CVE-2025-28233 | 2026-04-15 | 9.1 Critical | ||
| Incorrect access control in BW Broadcast TX600 (14980), TX300 (32990) (31448), TX150, TX1000, TX30, and TX50 Hardware Version: 2, Software Version: 1.6.0, Control Version: 1.0, AIO Firmware Version: 1.7 allows attackers to access log files and extract session identifiers to execute a session hijacking attack. | ||||
| CVE-2024-51996 | 1 Symphony Php Framework | 1 Symphony Process | 2026-04-15 | 7.5 High |
| Symphony process is a module for the Symphony PHP framework which executes commands in sub-processes. When consuming a persisted remember-me cookie, Symfony does not check if the username persisted in the database matches the username attached with the cookie, leading to authentication bypass. This vulnerability is fixed in 5.4.47, 6.4.15, and 7.1.8. | ||||
| CVE-2024-5201 | 2026-04-15 | 8.8 High | ||
| Privilege Escalation in OpenText Dimensions RM allows an authenticated user to escalate there privilege to the privilege of another user via HTTP Request | ||||
| CVE-2024-8315 | 2026-04-15 | N/A | ||
| An Improper Handling of Insufficient Permissions or Privileges vulnerability in scripts used in B&R APROL <4.4-00P5 may allow an authenticated local attacker to read credential information. | ||||
| CVE-2024-57155 | 1 Radar | 1 Radar | 2026-04-15 | 9.8 Critical |
| Incorrect access control in radar v1.0.8 allows attackers to bypass authentication and access sensitive APIs without a token. | ||||
| CVE-2025-52571 | 2026-04-15 | 9.7 Critical | ||
| Hikka is a Telegram userbot. A vulnerability affects all users of versions below 1.6.2, including most of the forks. It allows an unauthenticated attacker to gain access to Telegram account of a victim, as well as full access to the server. The issue is patched in version 1.6.2. No known workarounds are available. | ||||
| CVE-2024-55954 | 1 Openobserve | 1 Openobserve | 2026-04-15 | 8.7 High |
| OpenObserve is a cloud-native observability platform. A vulnerability in the user management endpoint `/api/{org_id}/users/{email_id}` allows an "Admin" role user to remove a "Root" user from the organization. This violates the intended privilege hierarchy, enabling a non-root user to remove the highest-privileged account. Due to insufficient role checks, the `remove_user_from_org` function does not prevent an "Admin" user from removing a "Root" user. As a result, an attacker with an "Admin" role can remove critical "Root" users, potentially gaining effective full control by eliminating the highest-privileged accounts. The `DELETE /api/{org_id}/users/{email_id}` endpoint is affected. This issue has been addressed in release version `0.14.1` and all users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||
| CVE-2025-29315 | 2026-04-15 | 9.8 Critical | ||
| An issue in the Shiro-based RBAC (Role-based Access Control) mechanism of OpenDaylight Service Function Chaining (SFC) Subproject SFC Sodium-SR4 and below allows attackers to execute privileged operations via a crafted request. | ||||
| CVE-2022-43110 | 1 Voltronicpower | 1 Viewpower | 2026-04-15 | 9.8 Critical |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. | ||||
| CVE-2024-6684 | 1 Gstelectronics | 1 Inohom Nova Panel N7 | 2026-04-15 | N/A |
| Authentication Bypass Using an Alternate Path or Channel vulnerability in GST Electronics inohom Nova Panel N7 allows Authentication Bypass.This issue affects inohom Nova Panel N7: through 1.9.9.6. NOTE: The vendor was contacted and it was learned that the product is not supported. | ||||
| CVE-2024-6697 | 1 Hitachi | 1 Vantara Pentaho Business Analytics Server | 2026-04-15 | 6.5 Medium |
| The product does not handle or incorrectly handles when it has insufficient privileges to access resources or functionality as specified by their permissions. This may cause it to follow unexpected code paths that may leave the product in an invalid state. (CWE-280) Hitachi Vantara Pentaho Business Analytics Server versions before 10.2.0.0 and 9.3.0.9, including 8.3.x, do not handle invalid and missing permissions correctly, resulting in a denial of service. An adversary leverages a legitimate capability of an application in such a way as to achieve a negative technical impact. | ||||
| CVE-2024-6727 | 2026-04-15 | 5.4 Medium | ||
| A flaw in versions of Delphix Data Control Tower (DCT) prior to 19.0.0 results in broken authentication through the enable-scale-testing functionality of the application. | ||||
| CVE-2024-51988 | 2026-04-15 | 6.5 Medium | ||
| RabbitMQ is a feature rich, multi-protocol messaging and streaming broker. In affected versions queue deletion via the HTTP API was not verifying the `configure` permission of the user. Users who had all of the following: 1. Valid credentials, 2. Some permissions for the target virtual host & 3. HTTP API access. could delete queues it had no (deletion) permissions for. This issue has been addressed in version 3.12.11 of the open source rabbitMQ release and in versions 1.5.2, 3.13.0, and 4.0.0 of the tanzu release. Users are advised to upgrade. Users unable to upgrade may disable management plugin and use, for example, Prometheus and Grafana for monitoring. | ||||
| CVE-2025-14095 | 2 Microsoft, Radiometer | 7 Windows, Abl800 Basic Analyzer, Abl800 Flex Analyzer and 4 more | 2026-04-15 | 5.7 Medium |
| A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software. Other related CVE's are CVE-2025-14096 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required configuration for Exposure: Physical access to the analyzer is needed. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note: CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems. | ||||
| CVE-2025-10847 | 1 Broadcom | 1 Unified Infrastructure Management | 2026-04-15 | N/A |
| DX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system. | ||||
| CVE-2025-46803 | 1 Gnu | 1 Screen | 2026-04-15 | 5 Medium |
| The default mode of pseudo terminals (PTYs) allocated by Screen was changed from 0620 to 0622, thereby allowing anyone to write to any Screen PTYs in the system. | ||||