In the Linux kernel, the following vulnerability has been resolved:
Input: synaptics-rmi4 - fix F55 transmitter electrode count typo
During F55 sensor detection, the transmitter (TX) electrode count was
incorrectly assigned the value of the receiver (RX) electrode count
due to copy-paste typos.
This incorrect value was then propagated to the driver data and used
by F54 to determine the diagnostics report size. On devices with more
RX than TX electrodes, this inflated the perceived TX count, leading
to incorrect report size calculations and potential out-of-bounds
buffer accesses.
Fix the typos by correctly assigning the TX electrode counts.
Input: synaptics-rmi4 - fix F55 transmitter electrode count typo
During F55 sensor detection, the transmitter (TX) electrode count was
incorrectly assigned the value of the receiver (RX) electrode count
due to copy-paste typos.
This incorrect value was then propagated to the driver data and used
by F54 to determine the diagnostics report size. On devices with more
RX than TX electrodes, this inflated the perceived TX count, leading
to incorrect report size calculations and potential out-of-bounds
buffer accesses.
Fix the typos by correctly assigning the TX electrode counts.
Advisories
No advisories yet.
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
Thu, 03 Sep 2026 07:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts. | |
| Title | Input: synaptics-rmi4 - fix F55 transmitter electrode count typo | |
| First Time appeared |
Linux
Linux linux Kernel |
|
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Linux
Linux linux Kernel |
|
| References |
|
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2026-09-03T08:26:33.180Z
Reserved: 2026-08-26T14:34:25.790Z
Link: CVE-2026-80754
No data.
No data.
No data.
OpenCVE Enrichment
No data.
Weaknesses
No weakness.