{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "Automation License Manager V6.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Automation License Manager V6.2", "vendor": "Siemens", "versions": [{"lessThan": "V6.2 Upd3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "CEMAT V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "CP PtP Param configuring interface", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Create MyConfig (CMC)", "vendor": "Siemens", "versions": [{"lessThan": "V6.9", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Energy Support Library (EnSL)", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "FM Configuration Package", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Modular PID CTRL Tool", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "MultiFieldbus Configuration Tool\u00a0(MFCT)", "vendor": "Siemens", "versions": [{"lessThan": "V1.5.5.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "OpenPCS 7 V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "OpenPCS 7 V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Siemens Network Planner (SINETPLAN)", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Automation Tool SDK Windows", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC BATCH V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Control Function Library (CFL) V1.x", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Control Function Library (CFL) V2.x", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Control Function Library (CFL) V3.x", "vendor": "Siemens", "versions": [{"lessThan": "V3.1.0.2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Control Function Library (CFL) V4.x", "vendor": "Siemens", "versions": [{"lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC\u00a0D7-SYS", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC eaSie Core Package", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC eaSie Document Skills", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC eaSie PCS 7 Skill Package", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC eaSie Workflow Skills", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Energy Suite V17", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Energy Suite V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Energy Suite V19", "vendor": "Siemens", "versions": [{"lessThan": "V19 Update 4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Logon V1.6", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Logon V2.0", "vendor": "Siemens", "versions": [{"lessThan": "V2.0 Upd3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Management Agent", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP1 Upd8", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Management Console", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP1 Upd8", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC MTP CREATOR\u00a0V2.x", "vendor": "Siemens", "versions": [{"lessThan": "V2.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC MTP CREATOR V3.x", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC MTP CREATOR V4.x", "vendor": "Siemens", "versions": [{"lessThan": "V4.1.0.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC MTP CREATOR\u00a0V5.x", "vendor": "Siemens", "versions": [{"lessThan": "V5.0.0.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC MTP Integrator V1.x", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC MTP Integrator V2.x", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC NET PC Software V19", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC NET PC Software V20", "vendor": "Siemens", "versions": [{"lessThan": "V20.0 Update 1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC ODK 1500S", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Faceplates V9.1", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP2 Upd4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Functions V2.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Functions V2.2", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Graphics V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Graphics V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Advanced Process Library V9.1", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP2 Upd6", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Basis Faceplates V9.1", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP2 Upd2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Basis Library V10.0", "vendor": "Siemens", "versions": [{"lessThan": "V10.0 SP1 Upd2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Basis Library V9.1", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP2 Upd8", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Industry Library V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Industry Library V9.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Industry Library V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Logic Matrix V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Logic Matrix V9.1", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 Upd8", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 MPC Configurator", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 PowerControl", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Standard Chemical Library V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 Standard Chemical Library V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 TeleControl", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 V10.0", "vendor": "Siemens", "versions": [{"lessThan": "V10.0 SP1 UC01", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [{"lessThan": "V9.1 SP1 UC08", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS 7/OPEN OS V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS neo V5.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PCS neo V6.0", "vendor": "Siemens", "versions": [{"lessThan": "V6.0 SP1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PDM Maintenance Station V5.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PDM V9.2", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC PDM V9.3", "vendor": "Siemens", "versions": [{"lessThan": "V9.3 SP1 Upd2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Process Function Library (PFL) V4.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Process Historian 2020", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Process Historian 2022", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Process Historian 2024", "vendor": "Siemens", "versions": [{"lessThan": "V2024 SP1 Upd2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC ProSave V17", "vendor": "Siemens", "versions": [{"lessThan": "V17 Update 9", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC ProSave V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC ProSave V19", "vendor": "Siemens", "versions": [{"lessThan": "V19 Update 4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC ProSave V20", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Route Control V10.0", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7 F Systems V6.3", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7 F Systems V6.4", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V2", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V3", "vendor": "Siemens", "versions": [{"lessThan": "V31.1.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)", "vendor": "Siemens", "versions": [{"lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-PCT", "vendor": "Siemens", "versions": [{"lessThan": "V3.5 SP4 Update 1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [{"lessThan": "V7.0 Update 1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM V17", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM V19", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM V20", "vendor": "Siemens", "versions": [{"lessThan": "V20 Update 1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Safety Matrix", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC STEP 7 CFC V19", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC STEP 7 CFC V20", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC STEP 7 V5.7", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Target", "vendor": "Siemens", "versions": [{"lessThan": "V6.0 SP3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC flexible ES", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [{"lessThan": "V17 Update 9", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional", "vendor": "Siemens", "versions": [{"lessThan": "V21", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V20", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC TeleControl", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Unified Line Coordination", "vendor": "Siemens", "versions": [{"lessThan": "V20", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Unified PC Runtime V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Unified PC Runtime V19", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Unified PC Runtime V20", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Unified Sequence", "vendor": "Siemens", "versions": [{"lessThan": "V20", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [{"lessThan": "V7.5 SP2 Update 20", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [{"lessThan": "V8.0 Update 8", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC V8.1", "vendor": "Siemens", "versions": [{"lessThan": "V8.1 Update 3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Visualization Architect (SiVArc) V17", "vendor": "Siemens", "versions": [{"lessThan": "V17 Update 9", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Visualization Architect (SiVArc) V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Visualization Architect (SiVArc) V19", "vendor": "Siemens", "versions": [{"lessThan": "V19 Update 4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC WinCC Visualization Architect (SiVArc) V20", "vendor": "Siemens", "versions": [{"lessThan": "V20 Update 3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMIT Rapid Tester", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMIT Simulation Platform", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SINAMICS Startdrive V17", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SINAMICS Startdrive V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SINAMICS Startdrive V19", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SINAMICS Startdrive V20", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [{"lessThan": "V4.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SINEMA Remote Connect Client", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SITRANS", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Standard PID CTRL Tool", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TeleControl Server Basic V3.1", "vendor": "Siemens", "versions": [{"lessThan": "V3.1.2.2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Administrator", "vendor": "Siemens", "versions": [{"lessThan": "V3.0.6", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Portal Cloud Connector", "vendor": "Siemens", "versions": [{"lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Portal Test Suite V17", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Portal Test Suite V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Portal Test Suite V19", "vendor": "Siemens", "versions": [{"lessThan": "V19 Update 4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Portal Test Suite V20", "vendor": "Siemens", "versions": [{"lessThan": "V20 Update 3", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Project-Server", "vendor": "Siemens", "versions": [{"lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "TIA Project-Server V17", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [{"lessThan": "V17 Update 9", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V19", "vendor": "Siemens", "versions": [{"lessThan": "V19 Update 4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V20", "vendor": "Siemens", "versions": [{"lessThan": "V20 Update 4", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "WinCC Panel Image Setup", "vendor": "Siemens", "versions": [{"lessThan": "V17 Update 9", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component."}, {"lang": "es", "value": "El componente de instalaci\u00f3n afectado es vulnerable al secuestro de DLL. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario cuando un usuario leg\u00edtimo instala una aplicaci\u00f3n que utiliza dicho componente."}], "id": "CVE-2025-30033", "lastModified": "2026-06-17T09:08:04.140", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2025-30033", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2025-08-12T20:10:10.615077Z", "version": "2.0.3"}}]}, "published": "2025-08-12T12:15:34.733", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-282044.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Deferred", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-427"}], "source": "productcert@siemens.com", "type": "Secondary"}]}