Search Results (645 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-52136 1 Emqx 1 Emqx 2026-04-15 3 Low
In EMQX before 5.8.6, administrators can install arbitrary novel plugins via the Dashboard web interface. NOTE: the Supplier's position is that this is the intended behavior; however, 5.8.6 adds a defense-in-depth feature in which a plugin's acceptability (for later Dashboard installation) is set by the "emqx ctl plugins allow" CLI command.
CVE-2025-24303 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 7.8 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-54427 1 Polkadot 1 Frontier 2026-04-15 N/A
Polkadot Frontier is an Ethereum and EVM compatibility layer for Polkadot and Substrate. The extrinsic note_min_gas_price_target is an inherent extrinsic, meaning only the block producer can call it. To ensure correctness, the ProvideInherent trait should be implemented for each inherent, which includes the check_inherent call. This allows other nodes to verify if the input (in this case, the target value) is correct. However, prior to commit a754b3d, the check_inherent function has not been implemented for note_min_gas_price_target. This lets the block producer set the target value without verification. The target is then used to set the MinGasPrice, which has an upper and lower bound defined in the on_initialize hook. The block producer can set the target to the upper bound. Which also increases the upper and lower bounds for the next block. Over time, this could result in continuously raising the gas price, making contract execution too expensive and ineffective for users. An attacker could use this flaw to manipulate the gas price, potentially leading to significantly inflated transaction fees. Such manipulation could render contract execution prohibitively expensive for users, effectively resulting in a denial-of-service condition for the network. This is fixed in version a754b3d.
CVE-2025-20093 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 8.2 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-33030 1 Intel 1 Npu Drivers 2026-04-15 3.3 Low
Improper conditions check in some firmware for some Intel(R) NPU Drivers within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a low complexity attack may enable data corruption. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (low) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-58354 1 Katacontainers 1 Kata-containers 2026-04-15 7.1 High
Kata Containers is an open source project focusing on a standard implementation of lightweight Virtual Machines (VMs) that perform like containers. In Kata Containers versions from 3.20.0 and before, a malicious host can circumvent initdata verification. On TDX systems running confidential guests, a malicious host can selectively fail IO operations to skip initdata verification. This allows an attacker to launch arbitrary workloads while being able to attest successfully to Trustee impersonating any benign workload. This issue has been patched in Kata Containers version 3.21.0.
CVE-2025-53638 2026-04-15 N/A
Solady is software that provides Solidity snippets with APIs. Starting in version 0.0.125 and prior to version 0.1.24, when an account is deployed via a proxy, using regular Solidity to call its initialization function may result in a silent failure, if the initialization function does not return a `bool` or some other return data. This is because regular Solidity uses `extcodesize(proxy)` to decide if call succeeds. This is insufficient in the case when the proxy points to an empty implementation. Users should upgrade to Solady v0.1.24 or later to receive a patch. Deploy any affected implementations and their factories on new EVM chains as soon as possible.
CVE-2024-23079 2026-04-15 6.2 Medium
JGraphT Core v1.5.2 was discovered to contain a NullPointerException via the component org.jgrapht.alg.util.ToleranceDoubleComparator::compare(Double, Double). NOTE: this is disputed by multiple third parties who believe there was not reasonable evidence to determine the existence of a vulnerability. The submission may have been based on a tool that is not sufficiently robust for vulnerability identification.
CVE-2025-22848 2026-04-15 3.5 Low
Improper conditions check for some Edge Orchestrator software for Intel(R) Tiber™ Edge Platform may allow an authenticated user to potentially enable denial of service via adjacent access.
CVE-2024-37372 2026-04-15 3.6 Low
The Permission Model assumes that any path starting with two backslashes \ has a four-character prefix that can be ignored, which is not always true. This subtle bug leads to vulnerable edge cases.
CVE-2024-52504 1 Siemens 1 Siprotec 4 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
CVE-2024-34360 2026-04-15 8.2 High
go-spacemesh is a Go implementation of the Spacemesh protocol full node. Nodes can publish activations transactions (ATXs) which reference the incorrect previous ATX of the Smesher that created the ATX. ATXs are expected to form a single chain from the newest to the first ATX ever published by an identity. Allowing Smeshers to reference an earlier (but not the latest) ATX as previous breaks this protocol rule and can serve as an attack vector where Nodes are rewarded for holding their PoST data for less than one epoch but still being eligible for rewards. This vulnerability is fixed in go-spacemesh 1.5.2-hotfix1 and Spacemesh API 1.37.1.
CVE-2024-38355 2026-04-15 7.3 High
Socket.IO is an open source, real-time, bidirectional, event-based, communication framework. A specially crafted Socket.IO packet can trigger an uncaught exception on the Socket.IO server, thus killing the Node.js process. This issue is fixed by commit `15af22fc22` which has been included in `socket.io@4.6.2` (released in May 2023). The fix was backported in the 2.x branch as well with commit `d30630ba10`. Users are advised to upgrade. Users unable to upgrade may attach a listener for the "error" event to catch these errors.
CVE-2025-10937 1 Nanoporetech 1 Minknow 2026-04-15 5.5 Medium
Oxford Nanopore Technologies' MinKNOW software at or prior to version 24.11 creates a temporary file to store the local authentication token during startup, before copying it to its final location. This temporary file is created in a directory accessible to all users on the system. An unauthorized local user or process can exploit this behavior by placing a file lock on the temporary token file using the flock system call. This prevents MinKNOW from completing the token generation process. As a result, no valid local token is created, and the software is unable to execute commands on the sequencer. This leads to a denial-of-service (DoS) condition, blocking sequencing operations.
CVE-2023-28910 2026-04-15 8 High
A specific flaw exists within the Bluetooth stack of the MIB3 infotainment system. The issue results from the disabled abortion flag eventually leading to bypassing assertion functions. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2024-57360 1 Gnu 1 Binutils 2026-04-15 5.5 Medium
https://www.gnu.org/software/binutils/ nm >=2.43 is affected by: Incorrect Access Control. The type of exploitation is: local. The component is: `nm --without-symbol-version` function.
CVE-2025-4675 1 Abb 2 Webpro Snmp Card Powervalue, Webpro Snmp Card Powervalue Ul 2026-04-15 6.5 Medium
Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
CVE-2025-20070 1 Intel 1 Intel Optane Pmem Management Software 2026-04-15 6.7 Medium
Improper conditions check for the Intel(R) Optane(TM) PMem management software before versions CR_MGMT_02.00.00.4052, CR_MGMT_03.00.00.0538 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable [cvss_threat_loss_factor]. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2024-10945 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 7.3 High
A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation.
CVE-2025-4619 1 Palo Alto Networks 1 Pan-os 2026-04-15 N/A
A denial-of-service (DoS) vulnerability in Palo Alto Networks PAN-OS software enables an unauthenticated attacker to reboot a firewall by sending a specially crafted packet through the dataplane. Repeated attempts to initiate a reboot causes the firewall to enter maintenance mode. This issue is applicable to the PAN-OS software versions listed below on PA-Series firewalls, VM-Series firewalls, and Prisma® Access software. This issue does not affect Cloud NGFW. ​​We have successfully completed the Prisma Access upgrade for all customers, with the exception of those facing issues such as conflicting maintenance windows. Remaining customers will be promptly scheduled for an upgrade through our standard upgrade process.