| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A Privilege Escalation through a Mass Assignment exists in Camaleon CMS
When a user wishes to change his password, the 'updated_ajax' method of the UsersController is called. The vulnerability stems from the use of the dangerous permit! method, which allows all parameters to pass through without any filtering. |
| Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution. |
| A vulnerability, which was classified as critical, was found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. Affected is the function reboot/restore of the file /cgi-bin/lighttpd.cgi of the component Web Interface. The manipulation leads to improper authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Integer Overflow or Wraparound vulnerability in dragonflydb dragonfly (src/redis/lua/struct modules). This vulnerability is associated with program files lua_struct.C.
This issue affects dragonfly: 1.30.1, 1.30.0, 1.28.18. |
| Path Traversal vulnerability in WF Steuerungstechnik GmbH airleader MASTER allows Retrieve Embedded Sensitive Data.This issue affects airleader MASTER: 3.0046. |
| mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system. |
| XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. Starting in version 4.3-milestone-1 and prior to versions 16.10.9, 17.4.2, and 17.5.0, the REST search URL is vulnerable to HQL injection via the `orderField` parameter. The specified value is added twice in the query, though, once in the field list for the select and once in the order clause, so it's not that easy to exploit. The part of the query between the two fields can be enclosed in single quotes to effectively remove them, but the query still needs to remain valid with the query two times in it. This has been patched in versions 17.5.0, 17.4.2, and 16.10.9. No known workarounds are available. |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could
cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a
crafted Modbus function call to tamper with memory area involved in memory size computation. |
| rfc3161-client is a Python library implementing the Time-Stamp Protocol (TSP) described in RFC 3161. Prior to version 1.0.3, there is a flaw in the timestamp response signature verification logic. In particular, chain verification is performed against the TSR's embedded certificates up to the trusted root(s), but fails to verify the TSR's own signature against the timestamping leaf certificates. Consequently, vulnerable versions perform insufficient signature validation to properly consider a TSR verified, as the attacker can introduce any TSR signature so long as the embedded leaf chains up to some root TSA. This issue has been patched in version 1.0.3. There is no workaround for this issue. |
| Emerson ValveLink Products store sensitive information in cleartext in memory. The
sensitive memory might be saved to disk, stored in a core dump, or
remain uncleared if the product crashes, or if the programmer does not
properly clear the memory before freeing it. |
| aws-mcp-server MCP server is vulnerable to command injection. An attacker can craft a prompt that once accessed by the MCP client will run arbitrary commands on the host system. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |
| CL4/6NX Plus and CL4/6NX-J Plus (Japan model) with the firmware versions prior to 1.15.5-r1 allow crafted dangerous files to be uploaded. An arbitrary Lua script may be executed on the system with the root privilege. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| ComfyUI-Bmad-Nodes is vulnerable to Code Injection. The issue stems from a validation bypass in the BuildColorRangeHSVAdvanced, FilterContour and FindContour custom nodes. In the entrypoint function to each node, there’s a call to eval which can be triggered by generating a workflow that injects a crafted string into the node. This can result in executing arbitrary code on the server. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| NetSarang Xmanager Enterprise 5.0 Build 1232, Xmanager 5.0 Build 1045, Xshell 5.0 Build 1322, Xftp 5.0 Build 1218, and Xlpd 5.0 Build 1220 contain a malicious nssock2.dll that implements a multi-stage, DNS-based backdoor. The dormant library contacts a C2 DNS server via a specially crafted TXT record for a month‑generated domain. After receiving a decryption key, it then downloads and executes arbitrary code, creates an encrypted virtual file system (VFS) in the registry, and grants the attacker full remote code execution, data exfiltration, and persistence. NetSarang released builds for each product line that remediated the compromise: Xmanager Enterprise Build 1236, Xmanager Build 1049, Xshell Build 1326, Xftp Build 1222, and Xlpd Build 1224. Kaspersky Lab identified an instance of exploitation in the wild in August 2017. |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |