| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in almaodo GmbH appinventor.ai_google.almando_control 2.3.1 allows a remote attacker to obtain sensitive information via the firmware update process |
| A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack. |
| A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS. |
| Missing authentication for critical function vulnerability exists in ID Link Manager and FUJITSU Software TIME CREATOR. If this vulnerability is exploited, sensitive information may be obtained and/or the information stored in the database may be altered by a remote authenticated attacker. |
| Incorrect access control in the fingerprint authentication mechanism of Bitdefender Mobile Security v4.11.3-gms allows attackers to bypass fingerprint authentication due to the use of a deprecated API. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication. |
| An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario. |
| Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application. |
| A vulnerability has been identified in which Rancher does not automatically clean up a user which has been deleted from the configured authentication provider (AP). This characteristic also applies to disabled or revoked users, Rancher will not reflect these modifications which may leave the user’s tokens still usable. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| The Control-M/Agent is vulnerable to unauthenticated remote code execution, arbitrary file read and write and similar unauthorized actions when mutual SSL/TLS authentication is not enabled (i.e. in the default configuration).
NOTE:
* The vendor believes that this vulnerability only occurs when documented security best practices are not followed. BMC has always strongly recommended to use security best practices such as configuring SSL/TLS between Control-M Server and Agent.
* The vendor notifies that Control-M/Agent is not impacted in Control-M SaaS |
| In version 0.4.1 of danswer-ai/danswer, a vulnerability exists where a basic user can create credentials and link them to an existing connector. This issue arises because the system allows an unauthenticated attacker to sign up with a basic account and perform actions that should be restricted to admin users. This can lead to excessive resource consumption, potentially resulting in a Denial of Service (DoS) and other significant issues, impacting the system's stability and security. |
| OPW Fuel Management Systems SiteSentinel
could allow an attacker to bypass authentication to the server and obtain full admin privileges. |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |
| Telesquare SKT LTE Router SDT-CS3B1 software version 1.2.0 contains an unauthenticated remote reboot vulnerability that allows attackers to trigger device reboot without authentication. Attackers can send POST requests to the lte.cgi endpoint with the Command=Reboot parameter to cause denial of service by forcing the router to restart. |
| A missing authentication for critical function vulnerability has been reported to affect QVR Pro. The remote attackers can then exploit the vulnerability to gain access to the system.
We have already fixed the vulnerability in the following version:
QVR Pro 2.7.4.14 and later |
| OneUptime is an open-source monitoring and observability platform. Prior to version 10.0.42, the Worker service's ManualAPI exposes workflow execution endpoints (GET /workflow/manual/run/:workflowId and POST /workflow/manual/run/:workflowId) without any authentication middleware. An attacker who can obtain or guess a workflow ID can trigger arbitrary workflow execution with attacker-controlled input data, enabling JavaScript code execution, notification abuse, and data manipulation. This issue has been patched in version 10.0.42. |
| A Missing Authentication for Critical Function vulnerability in command processing of Juniper Networks Junos OS allows a privileged local attacker to gain access to Linux-based line cards as root.
This issue affects systems running Junos OS using Linux-based line cards. Affected line cards include:
* MPC7, MPC8, MPC9, MPC10, MPC11
* LC2101, LC2103
* LC480, LC4800, LC9600
* MX304 (built-in FPC)
* MX-SPC3
* SRX5K-SPC3
* EX9200-40XS
* FPC3-PTX-U2, FPC3-PTX-U3
* FPC3-SFF-PTX
* LC1101, LC1102, LC1104, LC1105
This issue affects Junos OS:
* all versions before 22.4R3-S8,
* from 23.2 before 23.2R2-S6,
* from 23.4 before 23.4R2-S6,
* from 24.2 before 24.2R2-S3,
* from 24.4 before 24.4R2,
* from 25.2 before 25.2R2. |