| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| LEDVANCE com.ledvance.smartplus.eu 2.1.10 allows a remote attacker to obtain sensitive information via the firmware update process. |
| The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication. |
| A code execution security issue exists in the affected product. An attacker with physical access could abuse the maintenance menu of the controller with a crafted payload. The security issue can result in arbitrary code execution. |
| The health module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| An issue in almando GmbH Almando Play APP (com.almando.play) 1.8.2 allows a remote attacker to obtain sensitive information via the firmware update process |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the products does not have authentication features. |
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. |
| Simofa is a tool to help automate static website building and deployment. Prior to version 0.2.7, due to a design mistake in the RouteLoader class, some API routes may be publicly accessible when they should require authentication. This vulnerability has been patched in v0.2.7. |
| Insyde IHISI function 0x49 can restore factory defaults for certain UEFI variables without further authentication by default, which could lead to a possible roll-back attack in certain platforms. This is fixed in: kernel 5.2, version 05.29.19; kernel 5.3, version 05.38.19; kernel 5.4, version 05.46.19; kernel 5.5, version 05.54.19; kernel 5.6, version 05.61.19. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| A low privileged remote attacker may modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS. |
| A client-side remote code execution vulnerability exists in Hanwha Techwin Smart Security Manager (SSM) versions 1.32 and 1.4, due to improper restrictions on the PUT method exposed by the bundled Apache ActiveMQ instance (running on port 8161). An attacker can exploit this flaw through a Cross-Origin Resource Sharing (CORS) bypass combined with JavaScript-triggered file uploads to the web server, ultimately resulting in arbitrary code execution with SYSTEM privileges.
This vulnerability bypasses the server-side mitigations introduced in ZDI-15-156 and ZDI-16-481 by shifting the exploitation to the client-side.
This product is now referred to as Hanwha Wisenet SSM and it is unknown if current versions are affected. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a '/snapshot' endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the 'snapshot' endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment. |
| The affected products allow unauthenticated access to Open Network Video Interface Forum (ONVIF) services, which may allow an attacker unauthorized access to camera configuration information. |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| Siklu MultiHaul TG series devices before version 2.0.0 contain an unauthenticated vulnerability that allows remote attackers to retrieve randomly generated credentials via a network request. Attackers can send a specific hex-encoded command to port 12777 to obtain username and password, enabling direct SSH access to the device. |
| A vulnerability exists in Snap One OVRC cloud where an attacker can impersonate a Hub device and send requests to claim and unclaim devices. The attacker only needs to provide the MAC address of the targeted device and can make a request to unclaim it from its original connection and make a request to claim it. |
| Authentication Bypass
vulnerability in Hitachi Ops Center Analyzer on Linux, 64 bit (Hitachi Ops Center Analyzer detail view component), Hitachi Infrastructure Analytics Advisor on Linux, 64 bit (Hitachi Data Center Analytics
component
).This issue affects Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.3-00; Hitachi Infrastructure Analytics Advisor: from 2.1.0-00 through 4.4.0-00. |