Search Results (400 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-6834 2026-04-15 9 Critical
A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2025-50753 1 Mitrastar 1 Gpt-2741gnac-n2 2026-04-15 8.4 High
Mitrastar GPT-2741GNAC-N2 devices are provided with access through ssh into a restricted default shell.The command "deviceinfo show file" is supposed to be used from restricted shell to show files and directories. By providing " /bin/sh" (quotes included) to the argument of this command will drop a root shell.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-23395 2026-04-15 7.8 High
Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges
CVE-2024-27143 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 9.8 Critical
Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL.
CVE-2024-12673 1 Lenovo 1 Vantage 2026-04-15 7.8 High
An improper privilege vulnerability was reported in a BIOS customization feature of Lenovo Vantage on SMB notebook devices which could allow a local attacker to elevate privileges on the system. This vulnerability only affects Vantage installed on these devices: * Lenovo V Series (Gen 5) * ThinkBook 14 (Gen 6, 7) * ThinkBook 16 (Gen 6, 7) * ThinkPad E Series (Gen 1)
CVE-2024-52799 1 Argoproj 1 Argo-helm 2026-04-15 8.3 High
Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0.
CVE-2024-0073 2026-04-15 7.8 High
NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering.
CVE-2025-9055 3 Axis, Axis Communications Ab, Linux 3 Axis Os, Axis Os, Linux 2026-04-15 6.4 Medium
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2022-38691 1 Unisoc 4 Sc9863a, T310, T610 and 1 more 2026-04-15 7.8 High
In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2022-38695 2026-04-15 7.8 High
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2024-27110 2026-04-15 8.4 High
Elevation of privilege vulnerability in GE HealthCare EchoPAC products
CVE-2024-3330 2026-04-15 9.9 Critical
Vulnerability in Spotfire Spotfire Analyst, Spotfire Spotfire Server, Spotfire Spotfire for AWS Marketplace allows In the case of the installed Windows client: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code.This requires human interaction from a person other than the attacker., In the case of the Web player (Business Author): Successful execution of this vulnerability via the Web Player, will result in the attacker being able to run arbitrary code as the account running the Web player process, In the case of Automation Services: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code via Automation Services..This issue affects Spotfire Analyst: from 12.0.9 through 12.5.0, from 14.0 through 14.0.2; Spotfire Server: from 12.0.10 through 12.5.0, from 14.0 through 14.0.3, from 14.2.0 through 14.3.0; Spotfire for AWS Marketplace: from 14.0 before 14.3.0.
CVE-2024-28139 2026-04-15 8.8 High
The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2024-28140 2026-04-15 6.1 Medium
The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output.
CVE-2025-13911 2 Inductiveautomation, Microsoft 2 Ignition, Windows 2026-04-15 6.4 Medium
The vulnerability affects Ignition SCADA applications where Python scripting is utilized for automation purposes. The vulnerability arises from the absence of proper security controls that restrict which Python libraries can be imported and executed within the scripting environment. The core issue lies in the Ignition service account having system permissions beyond what an Ignition privileged user requires. When an authenticated administrator uploads a malicious project file containing Python scripts with bind shell capabilities, the application executes these scripts with the same privileges as the Ignition Gateway process, which typically runs with SYSTEM-level permissions on Windows. Alternative code execution patterns could lead to similar results.