| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.
A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network. |
| Prism Central versions prior to 2024.3.1 are vulnerable to a stored cross-site scripting attack via the Events component, allowing an attacker to hijack a victim user’s session and perform actions in their security context. |
| Due to an issue in configuration, code that was intended for debugging purposes was included in the market release of the ASPECT FW allowing an attacker to bypass authentication. This vulnerability may allow an attacker to change the system time, access files, and make function calls without prior authentication. This issue affects all versions of ASPECT prior to 3.08.04-s01 |
| A security issue exists due to improper handling of malformed CIP Forward Close packets during fuzzing. The controller enters a solid red Fault LED state and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF015. To recover, clear the fault. |
| SDG Technologies PnPSCADA allows a remote attacker to attach various entities without requiring system authentication. This breach could potentially lead to unauthorized control, data manipulation, and access to sensitive information within the SCADA system. |
| An OS command injection issue exists in Nimesa Backup and Recovery v2.3 and v2.4. If this vulnerability is exploited, an arbitrary OS commands may be executed on the server where the product is running. |
| Refit is an automatic type-safe REST library for .NET Core, Xamarin and .NET The various header-related Refit attributes (Header, HeaderCollection and Authorize) are vulnerable to CRLF injection. The way HTTP headers are added to a request is via the `HttpHeaders.TryAddWithoutValidation` method. This method does not check for CRLF characters in the header value. This means that any headers added to a refit request are vulnerable to CRLF-injection. In general, CRLF-injection into a HTTP header (when using HTTP/1.1) means that one can inject additional HTTP headers or smuggle whole HTTP requests. If an application using the Refit library passes a user-controllable value through to a header, then that application becomes vulnerable to CRLF-injection. This is not necessarily a security issue for a command line application like the one above, but if such code were present in a web application then it becomes vulnerable to request splitting (as shown in the PoC) and thus Server Side Request Forgery. Strictly speaking this is a potential vulnerability in applications using Refit and not in Refit itself. This issue has been addressed in release versions 7.2.22 and 8.0.0 and all users are advised to upgrade. There are no known workarounds for this vulnerability. |
| An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time' parameter of the '/protocol.csp?' endpoint. The input is processed by the internal date '-s' command without rebooting or disrupting HTTP service. Unlike other injection points, this vector allows remote compromise without triggering visible configuration changes. |
| An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). When configuring the device in WISP mode, the 'ssid' parameter is passed unsanitized to system-level scripts. This allows remote attackers within Wi-Fi range to inject arbitrary shell commands that execute as root, resulting in full device compromise. |
| Pgpool-II provided by PgPool Global Development Group contains an authentication bypass by primary weakness vulnerability. if the vulnerability is exploited, an attacker may be able to log in to the system as an arbitrary user, allowing them to read or tamper with data in the database, and/or disable the database. |
| A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created
over the web interface HTTP when enabled. HTTP is disabled by default. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| When the device is shared, the homepage module are before 2.19.0 in eWeLink Cloud Service allows Secondary user to take over devices as primary user via sharing unnecessary device-sensitive information. |
| A command injection vulnerability exists in LILIN Digital Video Recorder (DVR) devices prior to firmware version 2.0b60_20200207 via the Server field in the NTPUpdate configuration. The web service at /z/zbin/dvr_box fails to properly sanitize input, allowing remote attackers to inject and execute arbitrary commands as root by supplying specially crafted XML data to the DVRPOST interface. |
| The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system. |
| The ISOinsight from Netvision has a SQL Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary SQL commands to read, modify, and delete database contents. |
| Dongsheng Logistics Software exposes an unauthenticated endpoint at /CommMng/Print/UploadMailFile that fails to enforce proper file type validation and access control. An attacker can upload arbitrary files, including executable scripts such as .ashx, via a crafted multipart/form-data POST request. This allows remote code execution on the server, potentially leading to full system compromise. The vulnerability is presumed to affect builds released prior to July 2025 and is said to be remediated in newer versions of the product, though the exact affected range remains undefined. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-23 UTC. |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote attacker to execute arbitrary commands with elevated privileges.This issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller: through 2-5.95-4.Rt3352. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0. |