| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tinycontrol LAN Controller v3 LK3 version 1.58a contains an unauthenticated vulnerability that allows remote attackers to download configuration backup files containing sensitive credentials. Attackers can retrieve the lk3_settings.bin file and extract base64-encoded user and admin passwords without authentication. |
| When uploading organism or sequence data via the web interface,
GMOD Apollo
will unzip and inspect the files and will not check for path
traversal in supported archive types. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| A vulnerability was detected in Mercury KM08-708H GiGA WiFi Wave2 1.1.14. This affects an unknown function of the component HTTP Header Handler. The manipulation of the argument Host results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used. |
| The affected product is vulnerable to a command injection. An unauthenticated attacker could send commands through a malicious HTTP request which could result in remote code execution. |
| WRH-733GBK and WRH-733GWH contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in miniigd SOAP service. If a remote unauthenticated attacker sends a specially crafted request to the affected product, an arbitrary OS command may be executed. |
| CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| Exposure of Sensitive System Information to an Unauthorized Control Sphere vulnerability in Sharp Display Solutions projectors allows a attacker may improperly access the HTTP server and execute arbitrary actions. |
| Cap Collectif is an online decision making platform that integrates several tools. Before commit 812f2a7d271b76deab1175bdaf2be0b8102dd198, the `DebateAlternateArgumentsResolver` deserializes a `Cursor`, allowing any classes and which can be controlled by unauthenticated user. Exploitation of this vulnerability can lead to Remote Code Execution. The vulnerability is fixed in commit 812f2a7d271b76deab1175bdaf2be0b8102dd198. |
| Improper Validation of Integrity Check Value vulnerability in Sharp Display Solutions projectors allows a attacker may create and run unauthorized firmware. |
| Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting'), Improper Encoding or Escaping of Output, CWE - 83 Improper Neutralization of Script in Attributes in a Web Page vulnerability in Veribilim Software Veribase Order allows Stored XSS, Cross-Site Scripting (XSS), Exploit Script-Based APIs, XSS Through HTTP Headers.This issue affects Veribase Order: before v4.010.3. |
| Prototype pollution vulnerability in apidoc-core versions 0.2.0 and all subsequent versions allows remote attackers to modify JavaScript object prototypes via malformed data structures, including the “define” property processed by the application, potentially leading to denial of service or unintended behavior in applications relying on the integrity of prototype chains. This affects the preProcess() function in api_group.js, api_param_title.js, api_use.js, and api_permission.js worker modules. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| Budget Control Gateway acts as an entry point for incoming requests and routes them to the appropriate microservices for Budget Control. Budget Control Gateway does not properly validate auth tokens, which allows attackers to bypass intended restrictions. This vulnerability is fixed in 1.5.2. |
| An OS command injection vulnerability exists in Vinci Protocol Analyzer that could allow an attacker to escalate privileges and perform code execution on affected system. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| Emerson ValveLink Products store sensitive information in cleartext in memory. The
sensitive memory might be saved to disk, stored in a core dump, or
remain uncleared if the product crashes, or if the programmer does not
properly clear the memory before freeing it. |
| jj, or Jujutsu, is a Git-compatible VCS written in rust. In affected versions specially crafted Git repositories can cause `jj` to write files outside the clone. This issue has been addressed in version 0.23.0. Users are advised to upgrade. Users unable to upgrade should avoid cloning repos from unknown sources. |
| The iSherlock developed by HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. |