Search Results (2271 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2003-0190 4 Openbsd, Openpkg, Redhat and 1 more 8 Openssh, Openpkg, Enterprise Linux and 5 more 2026-04-16 N/A
OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack.
CVE-2001-0384 1 Siemens 1 Reliant Unix 2026-04-16 N/A
ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file.
CVE-2006-3344 1 Siemens 1 Speedstream Wireless Router 2026-04-16 N/A
Siemens Speedstream Wireless Router 2624 allows local users to bypass authentication and access protected files by using the Universal Plug and Play UPnP/1.0 component.
CVE-2020-8177 6 Debian, Fujitsu, Haxx and 3 more 19 Debian Linux, M10-1, M10-1 Firmware and 16 more 2026-04-15 7.8 High
curl 7.20.0 through 7.70.0 is vulnerable to improper restriction of names for files and other resources that can lead too overwriting a local file when the -J flag is used.
CVE-2018-16890 8 Canonical, Debian, F5 and 5 more 11 Ubuntu Linux, Debian Linux, Big-ip Access Policy Manager and 8 more 2026-04-15 7.5 High
libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.
CVE-2019-3822 7 Canonical, Debian, Haxx and 4 more 17 Ubuntu Linux, Debian Linux, Libcurl and 14 more 2026-04-15 9.8 Critical
libcurl versions from 7.36.0 to before 7.64.0 are vulnerable to a stack-based buffer overflow. The function creating an outgoing NTLM type-3 header (`lib/vauth/ntlm.c:Curl_auth_create_ntlm_type3_message()`), generates the request HTTP header contents based on previously received data. The check that exists to prevent the local buffer from getting overflowed is implemented wrongly (using unsigned math) and as such it does not prevent the overflow from happening. This output data can grow larger than the local buffer if very large 'nt response' data is extracted from a previous NTLMv2 header provided by the malicious or broken HTTP server. Such a 'large value' needs to be around 1000 bytes or more. The actual payload data copied to the target buffer comes from the NTLMv2 type-2 response header.
CVE-2026-25656 1 Siemens 3 Sinec-nms, Sinec Nms, User Management Component 2026-04-15 7.8 High
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3), User Management Component (UMC) (All versions < V2.15.2.1). The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with SYSTEM privileges.(ZDI-CAN-28108)
CVE-2024-32014 1 Siemens 1 Spectrum Power 4 2026-04-15 4.7 Medium
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to alter the local database which contains the application credentials. This allows an attacker to gain administrative application privileges.
CVE-2025-40800 1 Siemens 6 Comos, Nx, Simcenter 3d and 3 more 2026-04-15 7.4 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2024-45032 1 Siemens 2 Industrial Edge Management Pro, Industrial Edge Management Virtual 2026-04-15 10 Critical
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
CVE-2024-32639 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
CVE-2024-33498 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 5.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
CVE-2024-41170 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-52504 1 Siemens 1 Siprotec 4 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
CVE-2023-32737 1 Siemens 1 Simatic Step 7 2026-04-15 6.3 Medium
A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVE-2025-40587 1 Siemens 1 Polarion 2026-04-15 7.6 High
A vulnerability has been identified in Polarion V2404 (All versions < V2404.5), Polarion V2410 (All versions < V2410.2). The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application.
CVE-2025-40936 1 Siemens 1 Ps Iges Parasolid Translator Component 2026-04-15 7.8 High
A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755)
CVE-2024-43647 1 Siemens 14 Simatic S7-200 Smart Cpu Cr20s, Simatic S7-200 Smart Cpu Cr30s, Simatic S7-200 Smart Cpu Cr40 and 11 more 2026-04-15 7.5 High
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged.
CVE-2024-31978 1 Siemens 1 Sinec-nms 2026-04-15 7.6 High
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP2). Affected devices allow authenticated users to export monitoring data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download files from the file system. Under certain circumstances the downloaded files are deleted from the file system.
CVE-2024-33497 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 6.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.