| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A security flaw has been discovered in FlowiseAI Flowise up to 3.0.12. Affected is the function Login of the file packages/server/src/enterprise/services/account.service.ts of the component API Response Handler. The manipulation results in information disclosure. The attack can be launched remotely. A high complexity level is associated with this attack. The exploitability is told to be difficult. You should upgrade the affected component. |
| HCL DFXAnalytics is affected by an Improper Error Handling vulnerability where the application exposes detailed stack traces in responses, which could allow an attacker to gain insights into the application's internal structure, code logic, and environment configurations. |
| An authenticated (non-super) administrator can create a maintenance period with a JavaScript payload that is executed by any user that opens tooltip for that maintenance period in the Host navigator widget. This can allow the attacker to perform unauthorized actions depending on which user opens the tooltip. |
| A remote code execution vulnerability
exists in Notification Settings on GeoVision GV-ASWeb 6.2.0. An authenticated
user with System Setting permissions can execute arbitrary commands on the
server by sending a crafted HTTP POST request to the ASWebCommon.srf backend
endpoint to bypass the frontend restrictions. |
| In Paramiko through 4.0.0 before a448945, rsakey.py allows the SHA-1 algorithm. |
| Sandboxie-Plus is an open source sandbox-based isolation software for Windows. In versions 1.17.2 and earlier, an INI injection vulnerability allows any standard local user to bypass configuration restrictions (EditAdminOnly and ConfigPassword) and inject arbitrary directives into the global Sandboxie.ini configuration file. The background service skips authorization checks for IPC messages targeting sections beginning with UserSettings_, but does not sanitize CRLF characters in either the value parameter (via MSGID_SBIE_INI_ADD_SETTING) or the setting name parameter (via MSGID_SBIE_INI_SET_SETTING). An attacker can inject a new sandbox section header with unrestricted permissions, enabling sandbox escape and SYSTEM privilege escalation. This issue has been fixed in version 1.17.3. |
| Sandboxie-Plus is an open source sandbox-based isolation software for Windows. In versions 1.17.2 and earlier, a Time-of-Check-to-Time-of-Use (TOCTOU) race condition exists during addon installation. When a user installs an addon through the SandMan interface, UpdUtil.exe is spawned as SYSTEM by SbieSvc but stages files in the user-writable %TEMP%\sandboxie-updater directory. After UpdUtil verifies file hashes against the signed addon manifest, install.bat extracts files.cab and executes config.exe from its contents. Between hash verification and extraction, an unprivileged user can replace files.cab with a crafted cabinet containing a malicious executable, which is then run as SYSTEM. No UAC prompt is required.
This issue has been fixed in version 1.17.3. |
| OpenClaw before 2026.4.9 contains an authentication bypass vulnerability allowing untrusted workspace plugins to be auto-enabled during non-interactive onboarding when provider auth choices are shadowed. Attackers can exploit this by crafting malicious workspace plugins that are automatically selected and enabled during authentication setup without explicit user consent. |
| OpenClaw before 2026.4.10 contains an arbitrary file read vulnerability in QQBot media tags that allows attackers to reference host-local paths outside the intended media storage boundary. Attackers can craft malicious reply text containing media tags to disclose arbitrary local files through outbound media handling. |
| OpenClaw before 2026.4.14 contains a server-side request forgery vulnerability in browser SSRF policy that allows private-network navigation by default. Attackers can exploit this misconfiguration to access internal services or metadata endpoints through browser-driven requests. |
| vm2 is an open source vm/sandbox for Node.js. Prior to version 3.11.0, SuppressedError allows attackers to escape the sandbox and run arbitrary code. This issue has been patched in version 3.11.0. |
| Sandboxie-Plus is an open source sandbox-based isolation software for Windows. In versions 1.17.2 and earlier, SbieIniServer::HashPassword converts a SHA-1 digest to hexadecimal incorrectly. The high nibble of each byte is shifted right by 8 instead of 4, which always produces zero for an 8-bit value. As a result, the stored EditPassword hash only preserves the low nibble of each digest byte, reducing the effective entropy from 160 bits to 80 bits. This is layered on top of an unsalted SHA-1 scheme. The reduced entropy makes leaked or backed-up password hashes materially easier to brute-force.
This issue has been fixed in version 1.17.3. |
| Pi-hole FTL is the core engine of the Pi-hole network-level advertisement and tracker blocker. In versions before 6.6.1, the `dns.interface` configuration field in Pi-hole FTL accepted newline characters without validation, allowing an attacker to inject arbitrary directives into the generated dnsmasq configuration file. On installations with no admin password set (the default for many deployments), the configuration API is fully accessible without credentials, allowing a network-adjacent attacker to inject the payload, enable the built-in DHCP server, and achieve arbitrary command execution on the host the next time any device on the network requests a DHCP lease. The injected value is persisted to /etc/pihole/pihole.toml and survives restarts. The strncpy in the code path limits the total interface field to 31 bytes, but payloads such as wlan0\ndhcp-script=/tmp/p fit within this constraint. The dnsmasq config validation introduced in FTL 6.6 only checks syntactic validity, so valid directives injected via newline pass validation successfully. This issue has been fixed in version 6.6.1. |
| D-Link DIR-605L Hardware Revision A1 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn35_dlwbr_dir605l" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches. |
| HCL BigFix RunBookAI is affected by a Continued availability of Less-Secure “Input Text” Vulnerability . A component contains a security weakness in its input handling implementation, increasing the risk of misconfiguration and operational errors. |
| HCL BigFix RunBookAI is affected by a Unvalidated Command Input / Potential Command Smuggling vulnerability. A flaw in a component's input handling was identified that could permit unauthorized command execution. |
| D-Link DIR-605L Hardware Revision B2 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn76_dlwbr_dir605L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches. |
| D-Link DIR-600L Hardware Revision B1 (End-of-Life) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn61_dlwbr_dir600L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches. |
| D-Link DIR-600L Hardware Revision A1 (End-of-Life) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn35_dlwbr_dir600l" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches. |
| HCL DFXAnalytics is affected by an Insecure Security Header Configuration vulnerability where the application utilizes the outdated X-XSS-Protection header, which could allow an attacker to exploit browser-specific rendering flaws or bypass security controls that should instead be managed by a robust Content Security Policy (CSP). |