| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code. |
| Missing authentication for critical function vulnerability exists in ID Link Manager and FUJITSU Software TIME CREATOR. If this vulnerability is exploited, sensitive information may be obtained and/or the information stored in the database may be altered by a remote authenticated attacker. |
| Sensitive information disclosure due to missing authentication. The following products are affected: Acronis True Image (macOS) before build 41725, Acronis True Image (Windows) before build 41736, Acronis True Image OEM (macOS) before build 42571, Acronis True Image OEM (Windows) before build 42575. |
| An issue in the Arcadyan Livebox Fibra PRV3399B_B_LT allows a remote or local attacker to modify the GPON link value without authentication, causing an internet service disruption via the /firstconnection.cgi endpoint. |
| WorkOS Hosted AuthKit before 2025-01-07 allows a password authentication MFA bypass (by enrolling a new authentication factor) when the attacker knows the user's password. No exploitation occurred. |
| A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS. |
| A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack. |
| General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022. |
| Electrolink transmitters are vulnerable to an authentication bypass
vulnerability affecting the login cookie. An attacker can set an
arbitrary value except 'NO' to the login cookie and have full system
access. |
| A vulnerability has been identified in which Rancher does not automatically clean up a user which has been deleted from the configured authentication provider (AP). This characteristic also applies to disabled or revoked users, Rancher will not reflect these modifications which may leave the user’s tokens still usable. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2 |
| When configuring Arc (e.g. during the first setup), a local web interface is provided to ease the configuration process. Such web interface lacks authentication and may thus be abused by a local attacker or malware running on the machine itself.
A malicious local user or process, during a window of opportunity when the local web interface is active, may be able to extract sensitive information or change Arc's configuration. This could also lead to arbitrary code execution if a malicious update package is installed. |
| OPW Fuel Management Systems SiteSentinel
could allow an attacker to bypass authentication to the server and obtain full admin privileges. |
| DBPower C300 HD Camera contains a configuration disclosure vulnerability that allows unauthenticated attackers to retrieve sensitive credentials through an unprotected configuration backup endpoint. Attackers can download the configuration file and extract hardcoded username and password by accessing the /tmpfs/config_backup.bin resource. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |
| A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows a high privileged remote attacker to read files from the system’s file structure. |
| Nautobot Single Source of Truth (SSoT) is an app for Nautobot. Prior to version 3.10.0, an unauthenticated attacker could access this page to view the Service Now public instance name e.g. companyname.service-now.com. This is considered low-value information. This does not expose the Secret, the Secret Name, or the Secret Value for the Username/Password for Service-Now.com. An unauthenticated member would not be able to change the instance name, nor set a Secret. There is not a way to gain access to other pages Nautobot through the unauthenticated Configuration page. This issue has been patched in version 3.10.0. |
| In One Identity Identity Manager 9.x before 9.3, an insecure direct object reference (IDOR) vulnerability allows privilege escalation. Only On-Premise installations are affected. |