| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability in motherboard console ports of line cards for Cisco ASR 1000 Series Aggregation Services Routers and Cisco cBR-8 Converged Broadband Routers could allow an unauthenticated, physical attacker to access an affected device's operating system. The vulnerability exists because an engineering console port is available on the motherboard of the affected line cards. An attacker could exploit this vulnerability by physically connecting to the console port on the line card. A successful exploit could allow the attacker to gain full access to the affected device's operating system. This vulnerability affects only Cisco ASR 1000 Series Routers that have removable line cards and Cisco cBR-8 Converged Broadband Routers, if they are running certain Cisco IOS XE 3.16 through 16.5 releases. Cisco Bug IDs: CSCvc65866, CSCve77132. |
| An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android. The keystore is locked with a hard-coded password. Therefore, everyone with access to the keystore can read the content out, for example the private key of the user. |
| D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access. |
| The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG599 device, when IP Passthrough mode is not used, configures WAN access to a caserver https service with the tech account and an empty password, which allows remote attackers to obtain root privileges by establishing a session on port 49955 and then installing new software, such as BusyBox with "nc -l" support. |
| D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices use the same hardcoded /etc/stunnel.key private key across different customers' installations, which allows remote attackers to defeat the HTTPS cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| Toshiba Home gateway HEM-GW16A firmware HEM-GW16A-FW-V1.2.0 and earlier, Toshiba Home gateway HEM-GW26A firmware HEM-GW26A-FW-V1.2.0 and earlier uses hard-coded credentials, which may allow attackers to perform operations on device with administrative privileges. |
| D-Link DGS-1100 devices with Rev.B firmware 1.01.018 have a hardcoded SSL private key, which allows man-in-the-middle attackers to spoof devices by hijacking an HTTPS session. |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |
| Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |