| CVE-2022-38691 | 1 Unisoc | 4 Sc9863a, T310, T610 and 1 more | 2026-04-15 | 7.8 High |
| In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed. | ||||
| CVE-2022-38695 | 2026-04-15 | 7.8 High | ||
| In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed. | ||||
| CVE-2025-50505 | 1 Clash-verge | 1 Clash-verge | 2026-04-15 | 7.8 High |
| Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation. | ||||
| CVE-2022-38694 | 2026-04-15 | 7.8 High | ||
| In BootRom, there is a possible unchecked write address. This could lead to local escalation of privilege with no additional execution privileges needed. | ||||
| CVE-2023-41092 | 2026-04-15 | 7.6 High | ||
| Unchecked return value in SDM firmware for Intel(R) Stratix 10 and Intel(R) Agilex 7 FPGAs before version 23.3 may allow an authenticated user to potentially enable denial of service via adjacent access. | ||||
| CVE-2025-61680 | 2 Jaketcooper, Minecraft | 2 Minecraft-rcon, Minecraft | 2026-04-15 | N/A |
| Minecraft RCON Terminal is a VS Code extension that streamlines Minecraft server management. Versions 0.1.0 through 2.0.6 stores passwords using VS Code's configuration API which writes to settings.json in plaintext. This issue is fixed in version 2.1.0. | ||||
| CVE-2024-51552 | 1 Abb | 3 Aspect Enterprise, Matrix Series, Nexus Series | 2026-04-15 | 6 Medium |
| Weak password storage vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. | ||||
| CVE-2025-14295 | 2 Automatedlogic, Carrier | 2 Webctrl, I-vu | 2026-04-15 | N/A |
| Storing Passwords in a Recoverable Format vulnerability in Automated Logic WebCTRL on Windows, Carrier i-Vu on Windows. Storing Passwords in a Recoverable Format vulnerability (CWE-257) in the Web session management component allows an attacker to access stored passwords in a recoverable format which makes them subject to password reuse attacks by malicious users.This issue affects WebCTRL: from 6.0 through 9.0; i-Vu: from 6.0 through 9.0. | ||||
| CVE-2024-27488 | 1 Zlmediakit | 1 Zlmediakit | 2026-04-15 | 9.8 Critical |
| Incorrect Access Control vulnerability in ZLMediaKit versions 1.0 through 8.0, allows remote attackers to escalate privileges and obtain sensitive information. The application system enables the http API interface by default and uses the secret parameter method to authenticate the http restful api interface, but the secret is hardcoded by default. | ||||
| CVE-2024-28139 | 2026-04-15 | 8.8 High | ||
| The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future. | ||||
| CVE-2024-39922 | 2026-04-15 | 4.6 Medium | ||
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. | ||||
| CVE-2024-40116 | 1 Solar-log | 1 Solar-log 1000 Firmware | 2026-04-15 | 8.1 High |
| An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base. | ||||
| CVE-2025-30106 | 2026-04-15 | 8.8 High | ||
| On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing. | ||||
| CVE-2024-34539 | 2026-04-15 | 9.4 Critical | ||
| Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions. | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2025-2355 | 2026-04-15 | 3.3 Low | ||
| A vulnerability was found in BlackVue App 3.65 on Android and classified as problematic. Affected by this issue is some unknown functionality of the component API Endpoint Handler. The manipulation of the argument BCS_TOKEN/SECRET_KEY leads to unprotected storage of credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-9380 | 1 Fnkvision | 1 Y215 Cctv Camera | 2026-04-15 | 7.8 High |
| A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-25825 | 1 Fydeos | 2 Fydeos, Openfyde | 2026-04-15 | 9.8 Critical |
| FydeOS for PC 17.1 R114, FydeOS for VMware 17.0 R114, FydeOS for You 17.1 R114, and OpenFyde R114 were discovered to be configured with the root password saved as a wildcard. This allows attackers to gain root access without a password. | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||