| A Improper Input Validation issue affecting the v2_sdk_service running on a set of DJI drone devices on the port 10000 could allow an attacker to cause a crash of the service through a crafted payload triggering a missing input size check in the pull_file_v2_proc function implemented in the libv2_sdk.so library used by the dji_vtwo_sdk binary implementing the service, compromising it in a term of availability and producing a denial-of-service attack. Affected models are Mavic 3 Pro until v01.01.0300, Mavic 3 until v01.00.1200, Mavic 3 Classic until v01.00.0500, Mavic 3 Enterprise until v07.01.10.03, Matrice 300 until v57.00.01.00, Matrice M30 until v07.01.0022 and Mini 3 Pro until v01.00.0620. |
| perl2exe <= V30.10C contains an arbitrary code execution vulnerability that allows local authenticated attackers to execute malicious scripts. Attackers can control the 0th argument of packed executables to execute another executable, allowing them to bypass restrictions and gain unauthorized access. |
| Zincati is an auto-update agent for Fedora CoreOS hosts. Zincati ships a polkit rule which allows the `zincati` system user to use the actions `org.projectatomic.rpmostree1.deploy` to deploy updates to the system and `org.projectatomic.rpmostree1.finalize-deployment` to reboot the system into the deployed update. Since Zincati v0.0.24, this polkit rule contains a logic error which broadens access of those polkit actions to any unprivileged user rather than just the `zincati` system user. In practice, this means that any unprivileged user with access to the system D-Bus socket is able to deploy older Fedora CoreOS versions (which may have other known vulnerabilities). Note that rpm-ostree enforces that the selected version must be from the same branch the system is currently on so this cannot directly be used to deploy an attacker-controlled update payload. This primarily impacts users running untrusted workloads with access to the system D-Bus socket. Note that in general, untrusted workloads should not be given this access, whether containerized or not. By default, containers do not have access to the system D-Bus socket. The logic error is fixed in Zincati v0.0.30. A workaround is to manually add a following polkit rule, instructions for which are available in the GitHub Security Advisory. |
| Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution. |
| Reachable assertions in the NGAP_FIND_PROTOCOLIE_BY_ID function of OpenAirInterface Magma v1.8.0 and OAI EPC Federation v1.2.0 allow attackers to cause a Denial of Service (DoS) via a crafted NGAP packet. |
| In the Mullvad VPN client 2024.6 (Desktop), 2024.8 (iOS), and 2024.8-beta1 (Android), the exception-handling alternate stack can be exhausted, leading to heap-based out-of-bounds writes in enable() in exception_logging/unix.rs, aka MLLVD-CR-24-01. NOTE: achieving code execution is considered non-trivial. |
| A vulnerability in the web-based management interface and in the API subsystem of Cisco Tetration could allow an authenticated, remote attacker to inject arbitrary commands to be executed with root-level privileges on the underlying operating system.
This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by submitting a crafted HTTP message to the affected system. A successful exploit could allow the attacker to execute commands with root-level privileges. To exploit this vulnerability, an attacker would need valid administrator-level credentials.Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. |
| SonarQube Server and Cloud is a static analysis solution for continuous code quality and security inspection. A command injection vulnerability exists in SonarQube GitHub Action in version 4.0.0 to before version 6.0.0 when workflows pass user-controlled input to the args parameter on Windows runners without proper validation. This vulnerability bypasses a previous security fix and allows arbitrary command execution, potentially leading to exposure of sensitive environment variables and compromise of the runner environment. The vulnerability has been fixed in version 6.0.0. Users should upgrade to this version or later. |
| aws-mcp-server MCP server is vulnerable to command injection. An attacker can craft a prompt that once accessed by the MCP client will run arbitrary commands on the host system. |
| mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system. |
| Software installed and run as a non-privileged user may conduct improper GPU system calls resulting in platform instability and reboots. |
| The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow. |
| A vulnerability was found in Fujian Kelixun 1.0. It has been classified as critical. This affects an unknown part of the file /app/fax/fax_view.php of the component Filename Handler. The manipulation of the argument fax_file leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The pwrstudio web application of EV Charger (in the server in Circontrol Raption through 5.6.2) is vulnerable to OS command injection via three fields of the configuration menu for ntpserver0, ntpserver1, and pingip. |
| An issue in htop-dev htop v.2.20 allows a local attacker to cause an out-of-bounds access in the Header_populateFromSettings function. |
| The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| Factorio before 1.1.101 allows a crafted server to execute arbitrary code on clients via a custom map that leverages the ability of certain Lua base module functions to execute bytecode and generate fake objects. |
| Insecure handling of GET header parameter file included in requests being sent to an instance of the open-source project Phoniebox allows an attacker to create a website, which – when visited by a user – will send malicious requests to multiple hosts on the local network. If such a request reaches the server, it will cause one of the following (depending on the chosen payload): shell command execution, reflected XSS or cross-site request forgery.
This issue affects Phoniebox in all releases through 2.7. Newer 2.x releases were not tested, but they might also be vulnerable.
Phoniebox in version 3.0 and higher are not affected. |
| An OS Command Injection vulnerability affecting Station Launcher App in 3DEXPERIENCE platform from Release 3DEXPERIENCE R2022x through Release 3DEXPERIENCE R2025x could allow an attacker to execute arbitrary code on the user's machine. |
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). |