| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A Buffer Overflow vulnerabilty in the local_app_set_router_token function of Vilo 5 Mesh WiFi System <= 5.16.1.33 allows remote, unauthenticated attackers to execute arbitrary code via sscanf reading the token and timezone JSON fields into a fixed-length buffer. |
| Best Practical Request Tracker (RT) before 4.4.9, 5.0.9, and 6.0.2 allows CSV Injection via ticket values when TSV export is used. |
| ZOC Terminal 7.25.5 contains a denial of service vulnerability in the private key file input field that allows attackers to crash the application. Attackers can overwrite the private key file input with a 2000-byte buffer, causing the application to become unresponsive when attempting to create SSH key files. |
| Out-of-bounds Read vulnerability (CWE-125) was found in CX-Programmer. Attackers may be able to read sensitive information or cause an application crash by abusing this vulnerability. |
| A crafted network packet may cause a buffer overrun in Wind River VxWorks 7 through 23.09. |
| Out-of-bounds read in some Intel(R) VPL software before version 24.1.4 may allow an authenticated user to potentially enable information disclosure via local access. |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.
This could allow an unauthenticated remote attacker to execute arbitrary code. |
| The HTTPD binary in multiple ZTE routers has a stack-based buffer overflow vulnerability in rsa_decrypt function. This function is an API wrapper for LUA to decrypt RSA encrypted ciphertext, the decrypted data is stored on the stack without checking its length. An authenticated attacker can get RCE as root by exploiting this vulnerability. |
| The HTTPD binary in multiple ZTE routers has a stack-based buffer overflow vulnerability in webPrivateDecrypt function. This function is responsible for decrypting RSA encrypted ciphertext, the encrypted data is supplied base64 encoded. The decoded ciphertext is stored on the stack without checking its length. An unauthenticated attacker can get RCE as root by exploiting this vulnerability. |
| The HTTPD binary in multiple ZTE routers has a stack-based buffer overflow vulnerability in check_data_integrity function. This function is responsible for validating the checksum of data in post request. The checksum is sent encrypted in the request, the function decrypts it and stores the checksum on the stack without validating it. An unauthenticated attacker can get RCE as root by exploiting this vulnerability. |
| Buffer overflow vulnerability in H3C FA3010L access points SWFA1B0V100R005 due to the lack of length verification, which is related to the setting of firewall rules. Attackers who successfully exploit this vulnerability can cause the remote target device to crash or execute arbitrary commands. |
| Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.
This issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior. |
| The web interface of the affected devices processes a cookie value improperly, leading to a stack buffer overflow. More precisely, giving too long character string to MFPSESSIONID parameter results in a stack buffer overflow. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE.
When the REST interface is enabled by the user, and an attacker gains access to
the control network, and user/password broker authentication is enabled, and
CVE-2025-6074 is exploited, the attacker can overflow the buffer for username or
password.
This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016. |
| Net::IMAP implements Internet Message Access Protocol (IMAP) client functionality in Ruby. Starting in version 0.3.2 and prior to versions 0.3.8, 0.4.19, and 0.5.6, there is a possibility for denial of service by memory exhaustion in `net-imap`'s response parser. At any time while the client is connected, a malicious server can send can send highly compressed `uid-set` data which is automatically read by the client's receiver thread. The response parser uses `Range#to_a` to convert the `uid-set` data into arrays of integers, with no limitation on the expanded size of the ranges. Versions 0.3.8, 0.4.19, 0.5.6, and higher fix this issue. Additional details for proper configuration of fixed versions and backward compatibility are available in the GitHub Security Advisory. |
| An issue was discovered in Ruby 3.x through 3.3.0. If attacker-supplied data is provided to the Ruby regex compiler, it is possible to extract arbitrary heap data relative to the start of the text, including pointers and sensitive strings. The fixed versions are 3.0.7, 3.1.5, 3.2.4, and 3.3.1. |
| Extreme Networks IQ Engine before 10.6r1a, and through 10.6r4 before 10.6r5, has a buffer overflow. This issue arises from the ah_webui service, which listens on TCP port 3009 by default. |
| Buffer Overflow vulnerability in msoulier tftpy commit 467017b844bf6e31745138a30e2509145b0c529c allows a remote attacker to cause a denial of service via the parse function in the TftpPacketFactory class. |
| Out-of-bounds Read vulnerability in ASR1903、ASR3901 in ASR Lapwing_Linux on Linux (nr_fw modules). This vulnerability is associated with program files Code/nr_fw/DLP/src/NrCgi.C.
This issue affects Lapwing_Linux: before 2025/11/26. |
| Fuji Electric Smart Editor is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. |