| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Grafana is an open-source platform for monitoring and observability. Versions prior to 9.2.4, or 8.5.15 on the 8.X branch, are subject to Improper Input Validation. Grafana admins can invite other members to the organization they are an admin for. When admins add members to the organization, non existing users get an email invite, existing members are added directly to the organization. When an invite link is sent, it allows users to sign up with whatever username/email address the user chooses and become a member of the organization. This introduces a vulnerability which can be used with malicious intent. This issue is patched in version 9.2.4, and has been backported to 8.5.15. There are no known workarounds. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| Pix-Link LV-WR21Q does not enforce any form of authentication for endpoint /goform/getHomePageInfo. Remote unauthenticated attacker is able to use this endpoint to e.g: retrieve cleartext password to the access point.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version V108_108 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| The application does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it possible for an attacker to guess user credentials. |
| IC Realtime ICIP-P2012T 2.420 is vulnerable to Incorrect Access Control via an exposed HTTP channel using VLC network. |
| The FTP server’s login mechanism does not restrict authentication attempts, allowing an attacker to brute-force user passwords and potentially compromising the FTP server. |
| A Missing Authentication for Critical Function vulnerability in Juniper Networks Security Director Policy Enforcer allows an unauthenticated, network-based attacker to replace legitimate vSRX images with malicious ones.
If a trusted user initiates deployment, Security Director Policy Enforcer will deliver the attacker's uploaded image to VMware NSX instead of a legitimate one.
This issue affects Security Director Policy Enforcer:
* All versions before 23.1R1 Hotpatch v3.
This issue does not affect Junos Space Security Director Insights. |
| Missing Authentication for Critical Function vulnerability in Centreon Infra Monitoring centreon-awie (Awie import module) allows Accessing Functionality Not Properly Constrained by ACLs.
This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.3, from 24.04.0 before 24.04.3. |
| Authentication Bypass by Primary Weakness vulnerability in Jamf Jamf Pro allows unspecified impact.This issue affects Jamf Pro: from 11.20 through 11.24. |
| A vulnerability in Palantir's Aries service allowed unauthenticated access to log viewing and management functionality on Apollo instances using default configuration. The defect resulted in both authentication and authorization checks being bypassed, potentially allowing any network-accessible client to view system logs and perform operations without valid credentials. No evidence of exploitation was identified during the vulnerability window. |
| Enel X JuiceBox 40 Telnet Service Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Enel X JuiceBox 40 charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the telnet service, which listens on TCP port 2000 by default. The issue results from the lack of authentication prior to allowing remote connections. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-23285. |
| IAQS and I6 developed by JNC has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly operate system administrative functionalities. |
| A user with device administrative privileges can change existing SMTP server settings on the device, without having to re-enter SMTP server credentials. By redirecting send-to-email traffic to the new server, the original SMTP server credentials may potentially be exposed. |
| Police Statistics Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents by using a specific functionality. |
| Statistics Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly exploit a specific functionality to query database contents. |
| An Authentication Bypass by Primary Weakness
in the FTP server of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to get limited read-write access to files on the device.
When the FTP server is enabled and a user named "ftp" or "anonymous" is configured, that user can login without providing the configured password and then has read-write access to their home directory.
This issue affects Junos OS:
* all versions before 22.4R3-S8,
* 23.2 versions before 23.2R2-S3,
* 23.4 versions before 23.4R2. |
| A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point. |
| The Really Simple Security (Free, Pro, and Pro Multisite) plugins for WordPress are vulnerable to authentication bypass in versions 9.0.0 to 9.1.1.1. This is due to improper user check error handling in the two-factor REST API actions with the 'check_login_and_get_user' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, when the "Two-Factor Authentication" setting is enabled (disabled by default). |
| OPEXUS FOIAXpress Public Access Link (PAL) version v11.1.0 allows attackers to bypass account-lockout and CAPTCHA protections. Unauthenticated remote attackers can more easily brute force passwords. |