CVSS v3.1 |
| An information disclosure exists in Brave Browser Desktop prior to version 1.28.62, where logged warning messages that included timestamps of connections to V2 onion domains in tor.log. |
| When curl is instructed to get content using the metalink feature, and a user name and password are used to download the metalink XML file, those same credentials are then subsequently passed on to each of the servers from which curl will download or try to download the contents from. Often contrary to the user's expectations and intentions and without telling the user it happened. |
| Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file. |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device. |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device. |
| There is a Cleartext Transmission of Sensitive Information Vulnerability in Huawei Smartphone. Successful exploitation of this vulnerability may affect service confidentiality and availability. |
| There is an Information Disclosure vulnerability in Huawei Smartphone. Successful exploitation of this vulnerability may result in video streams being intercepted during transmission. |
| There is an information leak vulnerability in eCNS280_TD versions V100R005C00 and V100R005C10. A command does not have timeout exit mechanism. Temporary file contains sensitive information. This allows attackers to obtain information by inter-process access that requires other methods. |
| An issue has been discovered in GitLab affecting all versions starting from 11.6. Pull mirror credentials are exposed that allows other maintainers to be able to view the credentials in plain-text, |
| In all versions of GitLab, marshalled session keys were being stored in Redis. |
| Some PON MDU devices of ZTE stored sensitive information in plaintext, and users with login authority can obtain it by inputing command. This affects: ZTE PON MDU device ZXA10 F821 V1.7.0P3T22, ZXA10 F822 V1.4.3T6, ZXA10 F819 V1.2.1T5, ZXA10 F832 V1.1.1T7, ZXA10 F839 V1.1.0T8, ZXA10 F809 V3.2.1T1, ZXA10 F822P V1.1.1T7, ZXA10 F832 V2.00.00.01 |
| Dell EMC Unity, UnityVSA, and Unity XT versions prior to 5.0.7.0.5.008 contain a plain-text password storage vulnerability when the Dell Upgrade Readiness Utility is run on the system. The credentials of the Unisphere Administrator are stored in plain text. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user. |
| Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0. |
| TYPO3 is an open source PHP based web content management system. In TYPO3 before versions 6.2.57, 7.6.51, 8.7.40, 9.5.25, 10.4.14, 11.1.1 user session identifiers were stored in cleartext - without processing of additional cryptographic hashing algorithms. This vulnerability cannot be exploited directly and occurs in combination with a chained attack - like for instance SQL injection in any other component of the system. This is fixed in versions 6.2.57, 7.6.51, 8.7.40, 9.5.25, 10.4.14, 11.1.1. |
| OctopusDSC is a PowerShell module with DSC resources that can be used to install and configure an Octopus Deploy Server and Tentacle agent. In OctopusDSC version 4.0.977 and earlier a customer API key used to connect to Octopus Server is exposed via logging in plaintext. This vulnerability is patched in version 4.0.1002. |
| In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials. |
| In Fibaro Home Center 2 and Lite devices in all versions provide a web based management interface over unencrypted HTTP protocol. Communication between the user and the device can be eavesdropped to hijack sessions, tokens and passwords. |
| Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, and manipulation of the PLC output and/or suspension of the PLC may be conducted. |
| Video Insight VMS versions prior to 7.8 allows a remote attacker to execute arbitrary code with the system user privilege by sending a specially crafted request. |
| Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password. |