| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| CWE-798: Use of Hard-coded Credentials |
| An insecure sensitive key storage issue was found in MyASUS. potentially allowing unauthorized actor to obtain a token that could be used to communicate with certain services.
Refer to the 'Security Update for for MyASUS' section on the ASUS Security Advisory for more information. |
| Precor touchscreen console P82 contains a private SSH key that corresponds to a default public key. A remote attacker could exploit this to gain root privileges. |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| 'OfferBox' App for Android versions 2.0.0 to 2.3.17 and 'OfferBox' App for iOS versions 2.1.7 to 2.6.14 use a hard-coded secret key for JWT. Secret key for JWT may be retrieved if the application binary is reverse-engineered. |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| An high privileged remote attacker can enable telnet access that accepts hardcoded credentials. |
| Aptos Wisal payroll accounting before 7.1.6 uses hardcoded credentials in the Windows client to fetch the complete list of usernames and passwords from the database server, using an unencrypted connection. This allows attackers in a machine-in-the-middle position read and write access to personally identifiable information (PII) and especially payroll data and the ability to impersonate legitimate users with respect to the audit log. |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
| CWE-798 Use of Hard-coded Credentials |
| Ubiquiti U7-Pro 7.0.35 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: this is disputed by the Supplier because the observation only established that a password is present in a firmware image; however, the device cannot be deployed without setting a new password during installation. |
| Precor touchscreen console P62, P80, and P82 contains a default SSH public key in the authorized_keys file. A remote attacker could use this key to gain root privileges. |
| This vulnerability exists in ZKTeco WL20 due to hard-coded private key stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve private key stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to perform unauthorized decryption of sensitive data and Man-in-the-Middle (MitM) attacks on the targeted device. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |