| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing authentication for critical function in DAP-1880AC firmware version 1.21 and earlier allows a remote attacker to login to the device as an authenticated user without the access privilege via unspecified vectors. |
| Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting information without the access privileges via unspecified vectors. |
| Improper restriction of excessive authentication attempts in LOGITEC LAN-WH450N/GR allows an attacker in the wireless range of the device to recover PIN and access the network. |
| IBM Guardium Data Encryption (GDE) 3.0.0.2 and 4.0.0.4 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. |
| IBM Security Guardium 11.2 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 196314. |
| IBM Guardium Data Encryption (GDE) 4.0.0.4 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 196217. |
| A flaw was found in Keycloak 12.0.0 where re-authentication does not occur while updating the password. This flaw allows an attacker to take over an account if they can obtain temporary, physical access to a user’s browser. The highest threat from this vulnerability is to confidentiality, integrity, as well as system availability. |
| It was found in OpenShift Container Platform 4 that ignition config, served by the Machine Config Server, can be accessed externally from clusters without authentication. The MCS endpoint (port 22623) provides ignition configuration used for bootstrapping Nodes and can include some sensitive data, e.g. registry pull secrets. There are two scenarios where this data can be accessed. The first is on Baremetal, OpenStack, Ovirt, Vsphere and KubeVirt deployments which do not have a separate internal API endpoint and allow access from outside the cluster to port 22623 from the standard OpenShift API Virtual IP address. The second is on cloud deployments when using unsupported network plugins, which do not create iptables rules that prevent to port 22623. In this scenario, the ignition config is exposed to all pods within the cluster and cannot be accessed externally. |
| A flaw was found in the OpenShift Installer before version v0.9.0-master.0.20210125200451-95101da940b0. During installation of OpenShift Container Platform 4 clusters, bootstrap nodes are provisioned with anonymous authentication enabled on kubelet port 10250. A remote attacker able to reach this port during installation can make unauthenticated `/exec` requests to execute arbitrary commands within running containers. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability. |
| Trendnet AC2600 TEW-827DRU version 2.08B01 does not have sufficient protections for the UART functionality. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection. No username or password is required and the user is given a root shell with full control of the device. |
| Trendnet AC2600 TEW-827DRU version 2.08B01 contains an authentication bypass vulnerability. It is possible for an unauthenticated, malicous actor to force the change of the admin password due to a hidden administrative command. |
| Trendnet AC2600 TEW-827DRU version 2.08B01 lacks proper authentication to the bittorrent functionality. If enabled, anyone is able to visit and modify settings and files via the Bittorent web client by visiting: http://192.168.10.1:9091/transmission/web/ |
| Trendnet AC2600 TEW-827DRU version 2.08B01 improperly discloses information via redirection from the setup wizard. Authentication can be bypassed and a user may view information as Admin by manually browsing to the setup wizard and forcing it to redirect to the desired page. |
| ManageEngine Log360 Builds < 5235 are affected by an improper access control vulnerability allowing database configuration overwrite. An unauthenticated remote attacker can send a specially crafted message to Log360 to change its backend database to an attacker-controlled database and to force Log360 to restart. An attacker can leverage this vulnerability to achieve remote code execution by replacing files executed by Log360 on startup. |
| There exists an unauthenticated BLE Interface in Sloan SmartFaucets including Optima EAF, Optima ETF/EBF, BASYS EFX, and Flushometers including SOLIS. The vulnerability allows for unauthenticated kinetic effects and information disclosure on the faucets. It is possible to use the Bluetooth Low Energy (BLE) connectivity to read and write to many BLE characteristics on the device. Some of these control the flow of water, the sensitivity of the sensors, and information about maintenance. |
| Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to view sensitive syslog events without authentication. |
| A vulnerability in the spam quarantine feature of Cisco Secure Email and Web Manager, formerly Cisco Security Management Appliance (SMA), could allow an authenticated, remote attacker to gain unauthorized access and modify the spam quarantine settings of another user. This vulnerability exists because access to the spam quarantine feature is not properly restricted. An attacker could exploit this vulnerability by sending malicious requests to an affected system. A successful exploit could allow the attacker to modify another user's spam quarantine settings, possibly disabling security controls or viewing email messages stored on the spam quarantine interfaces. |
| A vulnerability in the web-based management interface of Cisco HyperFlex HX Data Platform could allow an unauthenticated, remote attacker to upload files to an affected device. This vulnerability is due to missing authentication for the upload function. An attacker could exploit this vulnerability by sending a specific HTTP request to an affected device. A successful exploit could allow the attacker to upload files to the affected device with the permissions of the tomcat8 user. |
| A vulnerability in the Self Care Portal of Cisco Unified Communications Manager (Unified CM) and Cisco Unified Communications Manager Session Management Edition (Unified CM SME) could allow an authenticated, remote attacker to modify data on an affected system without proper authorization. The vulnerability is due to insufficient validation of user-supplied data to the Self Care Portal. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected system. A successful exploit could allow the attacker to modify information without proper authorization. |
| Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory. |