| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| An issue in TOTOLINK-CX-A3002RU V1.0.4-B20171106.1512 and TOTOLINK-CX-N150RT V2.1.6-B20171121.1002 and TOTOLINK-CX-N300RT V2.1.6-B20170724.1420 and TOTOLINK-CX-N300RT V2.1.8-B20171113.1408 and TOTOLINK-CX-N300RT V2.1.8-B20191010.1107 and TOTOLINK-CX-N302RE V2.0.2-B20170511.1523 allows a remote attacker to execute arbitrary code via the /boafrm/formSysCmd component. |
| An issue in tiagorlampert CHAOS v5.0.1 before 1b451cf62582295b7225caf5a7b506f0bad56f6b and 24c9e109b5be34df7b2bce8368eae669c481ed5e allows a remote attacker to execute arbitrary code via the unsafe concatenation of the `filename` argument into the `buildStr` string without any sanitization or filtering. |
| home 5G HR02, Wi-Fi STATION SH-52B, and Wi-Fi STATION SH-54C contain an OS command injection vulnerability in the HOST name configuration screen. An arbitrary OS command may be executed with the root privilege by an administrative user. |
| An issue in Infotel Conseil GLPI v.10.X.X and after allows a remote attacker to execute arbitrary code via the insufficient validation of user-supplied input. |
| NVIDIA nvJPEG2000 library contains a vulnerability where an attacker can cause an out-of-bounds write issue by means of a specially crafted JPEG2000 file. A successful exploit of this vulnerability might lead to code execution and data tampering. |
| A flaw was found in the RPC library APIs of libvirt. The RPC server deserialization code allocates memory for arrays before the non-negative length check is performed by the C API entry points. Passing a negative length to the g_new0 function results in a crash due to the negative length being treated as a huge positive number. This flaw allows a local, unprivileged user to perform a denial of service attack by causing the libvirt daemon to crash. |
| ZEN Load Balancer versions 2.0 and 3.0-rc1 contain a command injection vulnerability in content2-2.cgi. The filelog parameter is passed directly into a backtick-delimited exec() call without sanitation. An authenticated attacker can inject arbitrary shell commands, resulting in remote code execution as the root user. ZEN Load Balancer is the predecessor of ZEVENET and SKUDONET. The affected versions (2.0 and 3.0-rc1) are no longer supported. SKUDONET CE is the current community-maintained successor. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in +F FS010M versions prior to V2.0.1_1101. If this vulnerability is exploited, an arbitrary OS command may be executed by a remote authenticated attacker. |
| Fujitsu fbiosdrv.sys before 2.5.0.0 allows an attacker to potentially affect system confidentiality, integrity, and availability. |
| An remote attacker with low privileges can perform a command injection which can lead to root access. |
| Out-of-bounds vulnerability in curve segmentation processing of Generic PCL6 V4 Printer Driver / Generic UFR II V4 Printer Driver / Generic LIPSLX V4 Printer Driver. |
| A vulnerability classified as critical has been found in mannaandpoem OpenManus up to 2025.3.13. This affects an unknown part of the file app/tool/python_execute.py of the component Prompt Handler. The manipulation leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Erroneously using an all-zero seed for RSA-OEAP padding instead of the generated random bytes, in Oberon microsystems AG’s Oberon PSA Crypto library in all versions up to 1.5.1, results in deterministic RSA and thus in a loss of confidentiality for guessable messages, recognition of repeated messages, and loss of security proofs. |
| Command injection vulnerability in Comtrend router WLD71-T1_v2.0.201820, affecting the GRG-4280us version. This vulnerability could allow an authenticated user to execute commands inside the router by making a POST request to the URL “/boaform/admin/formUserTracert”. |
| An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| Out-of-bounds write for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.160 within Ring 2: Device Drivers may allow a denial of service. Unprivileged software adversary with an unauthenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via adjacent access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (low) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (high) impacts. |
| An OS command injection vulnerability exists in the OptiLink ONT1GEW GPON router firmware version V2.1.11_X101 Build 1127.190306 and earlier. The router’s web management interface fails to properly sanitize user input in the target_addr parameter of the formTracert and formPing administrative endpoints. An authenticated attacker can inject arbitrary operating system commands, which are executed with root privileges, leading to remote code execution. Successful exploitation enables full compromise of the device. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| EnGenius ENH1350EXT A8J-ENH1350EXT devices through 3.9.3.2_c1.9.51 allow (blind) OS Command Injection via shell metacharacters to the Ping or Speed Test utility. During the time of initial setup, the device creates an open unsecured network whose admin panel is configured with the default credentials of admin/admin. An unauthorized attacker in proximity to the Wi-Fi network can exploit this window of time to execute arbitrary OS commands with root-level permissions. |
| Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software
versions before 1.979. A physically close
attacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes. |