| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.
This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1. |
| Authentication bypass by primary weakness vulnerability in ABB Freelance.
This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024. |
| Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| Incorrect Authorization vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. |
| Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface. |
| A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.
The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.
This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3. |
| Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| Predictable filename vulnerabilities in ASPECT may expose sensitive information to a potential attacker if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may
be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst)
This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2. |
| Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33. |
| Remote Code Execution vulnerabilities are present in ASPECT if session administra-tor credentials become compromised.
This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| Large content vulnerabilities are present in ASPECT exposing a device to disk overutilization on a system if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Sensitive device logger information in ASPECT may be exposed if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Stored Cross Site Scripting vulnerabilities exist in ASPECT if administrator creden-tials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| One way hash with predictable salt vulnerabilities in ASPECT may expose sensitive information to a potential attackerThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |